background image

| 3

FOR YOUR RECORDS:

Date of Purchase:

Generator Model Number:

Purchased from Store/Dealer:

Generator Serial Number:

IMPORTANT: KEEP YOUR PURCHASE RECEIPT TO ENSURE TROUBLE-FREE WARRANTY 

COVERAGE.

PRODUCT REGISTRATION

To ensure trouble-free warranty coverage, it is important you register your Rainier generator. 

You can register your generator by either:

1.  Filling in the product registration form below and mailing to:

 

Product Registration

 

Rainier Outdoor Power Equipment, LLC

 

777 Manor Park Drive

 

Columbus, Ohio 43228

2.  Registering your product Online at 

www.rainierpower.com/register

 

To register your generator you will need to locate the following information:

RAINIER PRODUCT REGISTRATION FORM

PERSONAL INFORMATION  

GENERATOR INFORMATION

First Name:

 _______________________________________

Model Number:

 _____________________________________

Last Name: 

 _______________________________________

Serial Number:

 ______________________________________

Street Address: 

 ___________________________________

Date Purchased:

 ____________________________________

Street Address: 

 ___________________________________

Purchased From:

 ____________________________________

City, State, ZIP:

 ____________________________________

Country:

 __________________________________________

Phone Number:

 ___________________________________

E-Mail:

 ___________________________________________

Содержание R4400

Страница 1: ...OPEN FRAME Generator 3600 Running Watts 4400 Peak Watts R4400...

Страница 2: ...cause you and others to be seriously hurt or killed Model Number Running Watts Peak Watts Gasoline Tank Size G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity qt Oil...

Страница 3: ...register your generator you will need to locate the following information RAINIER PRODUCT REGISTRATION FORM PERSONAL INFORMATION GENERATOR INFORMATION First Name _____________________________________...

Страница 4: ...ion Selection 12 Grounding the Generator 12 High Altitude Operation Conversion Kits 12 Power Cord 13 Engine Fluids and Fuel 14 Adding Gasoline to the Fuel Tank 14 Starting the Generator 15 Stopping th...

Страница 5: ...NGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CA...

Страница 6: ...uel cap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank with gasoline Keep sp...

Страница 7: ...ALLING FEET TO FRAME 1 Place generator on a flat surface 2 Place a piece of cardboard or other soft material to tip the generator onto to protect the frame paint and prevent the generator from sliding...

Страница 8: ...ery cables ALWAYS disconnect the negative battery cable black boot first when disconnecting battery cables NEVER connect the negative battery cable black boot to the positive post on the battery NEVER...

Страница 9: ...lug Dipstick Must be removed to add and check oil FEATURES Oil Drain Plug Must be removed to drain engine oil Never Flat Wheels For easy portability Single Piece Handle Includes rubber grip Allows you...

Страница 10: ...the engine or the spark plug CARB Canister Required for models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor prevents sparks from...

Страница 11: ...STOP to stop the engine Data Center The VFT Meter is an LED display that will rotate through volts frequency and lifetime run hours You can press the MODE button to cycle through the different display...

Страница 12: ...lectrical shock due to faulty appliances High Altitude Operation Engine power is reduced the higher you operate above sea level Output will be reduced approximately 3 5 for every 1000ft of increased a...

Страница 13: ...the responsibility of the user only This table is intended for reference only The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and...

Страница 14: ...perating the generator make sure to not exceed 50 of the rated running watts until the unit is broken in properly Make sure to vary to load occasionally to allow stator windings to heat and cool Adjus...

Страница 15: ...proper oil level can result in engine damage STARTING THE GENERATOR Be sure to check oil and gas levels before starting If it is the first time starting make sure to add oil 1 Make sure nothing is plu...

Страница 16: ...ables away from the battery posts to avoid arcing Allow hot components to cool to the touch prior to performing any maintenance procedure MAINTENANCE BEFORE PERFORMING MAINTENANCE ON THE GENERATOR REV...

Страница 17: ...ange Change Cooling Features Check Clean Air Filter Check Clean Replace Spark Plug Check Clean Replace Spark Arrestor Check Clean Service more frequently if operating in dry and dusty conditions TABLE...

Страница 18: ...With a damp rag clean around the oil fill plug dipstick 5 Remove oil fill plug dipstick Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick and wipe...

Страница 19: ...ities or reclamation facility AIR FILTER MAINTENANCE WARNING Never use gasoline or other flammable solvents to clean the air filter Use only household detergent soap to clean the air filter Cleaning t...

Страница 20: ...plug boot by firmly pulling the plastic spark plug boot handle directly away from the engine NOTICE Never apply any side load or move the spark plug laterally when removing the spark plug Applying a...

Страница 21: ...Switch is switched to STOP so the generator does not draw power from battery 2 Clean the generator as outlined in Cleaning the Generator 3 Drain all gasoline from the fuel tank as best as possible 4 D...

Страница 22: ...ck for overload condition 2 The power cord s plug connector is not fully engaged in the generator s outlet 2 Verify plug connector is firmly engaged in the generator s outlet 3 Faulty or defective pow...

Страница 23: ...nd clean the air filter 6 Low oil level shut down switch is preventing the unit from starting 6 Check oil level and add oil if necessary 7 Spark plug boot is not fully engaged with the spark plug tip...

Страница 24: ...ou must at your expense deliver or ship your Rainier generator to an Rainier Outdoor Power Equipment Authorized Service Dealer for warranty repairs which must occur within the applicable warranty peri...

Страница 25: ...rtime holiday or emergency labor Starting battery fuses light bulbs and engine fluids DISCLAIMER OF IMPLIED WARRANTIES This limited warranty is in lieu of all other expressed or implied warranties inc...

Страница 26: ...26...

Страница 27: ...27 Version 07 05 18KD Rev2 RainierPower com...

Отзывы: