| 15
OPERATION
BEFORE STARTING THE GENERATOR
BEFORE STARTING THE GENERATOR,
REVIEW SAFETY SECTION STARTING ON
PAGE 5.
Before attempting to start the generator,
verify the following:
• The engine is filled with engine oil.
• The generator is situated in a proper location.
• The generator is on a dry surface.
• All loads are disconnected from the generator.
• The generator is properly grounded the Generator.
DANGER
Never use the generator in a location that is wet or
damp. Never expose the generator to rain, snow,
water spray or standing water while in use. Protect
the generator from all hazardous weather conditions.
Moisture or ice can cause a short circuit or other
malfunction in the electrical circuit.
Never operate the generator in an enclosed area.
Engine exhaust contains carbon monoxide. Only
operate the generator outside and away from
windows, doors and vents.
NOTICE
The engine is equipped with a low oil shutdown switch. If the oil
level becomes low, the engine may shut down and not start until
the oil is filled to the proper level. Poor oil quality may interfere with
the operation of the low oil shutdown switch.
The owner of the generator is responsible to ensure the proper oil
level is maintained during the operation of the generator. Failure to
maintain the proper oil level can result in engine damage.
STARTING THE GENERATOR
Be sure to check oil and gas levels before starting. If it is
the first time starting make sure to add oil
.
1. Make sure nothing is plugged into power outlets.
2. Verify the battery is properly installed and both
battery cables are attached.
3. Make sure the circuit breakers are properly set.
4. Move the fuel shut off valve to the
ON
position.
ON
OFF
5. If engine is cold, move the choke lever to the
ON
position. If engine is warm move the choke to the
OFF
position.
6. Choose starting method:
a. Electric Start:
Push and hold the engine control
switch in the
START
position until the engine
starts. Once the engine starts, release the engine
control switch; the switch will automatically move
into the
RUN
position.
START
RUN
STOP
Note: If the engine fails to start after 5 seconds, release the
engine control switch. Let the generator sit idle for 15 seconds
and then repeat step 6a. If the cranking speed drops after each
unsuccessful attempt, then the battery may not be adequately
charged. Manually start the generator by following steps
below:
a. Manual Start:
Firmly grasp and pull the recoil
handle slowly until you feel increased resistance.
At this point, apply a rapid pull while pulling up
and slightly away from the generator.
6. As the engine starts and stabilizes, gradually move
the choke lever back to the
OFF
position.
7. Wait 15 seconds for engine to stabilize before
plugging in electronic devices.