Engine will not start or
remain running while
trying to start.
1. Fuel shutoff valve is in the OFF position.
1. Move the fuel shut off valve to the ON position.
2. Generator is out of gasoline.
2. Add gasoline to the generator.
3. Fuel flow is obstructed.
3. Inspect and clean fuel delivery passages.
4. Starting battery may have insufficient charge 4. On electric start models only. Check battery
output and charge battery as necessary.
5. Dirty air filter
5. Check and clean the air filter.
6. Low oil level shut down switch is preventing
the unit from starting.
6. Check oil level and add oil if necessary.
7. Spark plug boot is not fully engaged with
the spark plug tip.
7. Firmly push down on the spark plug boot to
ensure the boot is fully engaged
8. Spark plug is faulty.
8. Remove and check the spark plug. Replace if
faulty.
9. Dirty/plugged spark arrestor
9. Check and clean the spark arrestor.
10. Stale fuel
10. Drain fuel and replace with fresh fuel.
11. If trying 1-10 above does not solve the
problem, the cause might be the generator has
a fault.
11. Take the generator to your nearest authorized
service dealer.
TROUBLESHOOTING