(F) BALLAST FEATURES 

 

The micro-processor controlled electronic UV ballast supplied with your Rainfresh UV8B system has both audio and visual 
alarm indicators to indicate the lamp operation and an integral annual lamp change reminder timer. 

 
 

NORMAL DISPLAY:

 Number of days left before lamp expires and 

must be replaced. Starts at 365 and ends at 0.  

 

Press button to display the total running days of the unit since 
installation (maximum 9999 days). Display goes back to default 

after 10 seconds.  

 

“LF”

 - LAMP FAULT: If the lamp is disconnected or defective 

(burned out), the display with show “LF” and the ballast will beep every 2 seconds. If you press the button 

once, display will show “lamp life remaining” and go back to “LF” after 10 seconds. If you press the button again before 
10 seconds, display will show “total running time” and then after 10 seconds go back to “LF”. In the “LF” alarm do not 
consume water until you replace UV lamp and cleared the alarm. 

 

“A3

” – LAMP EXPIRY: If the display shows “A3” alarm with red LED on and ballast beeps every 5 seconds, it 

indicates that the lamp has expired.  

 

You can silence the alarm for 7 days by pressing and holding the button until “

dELy

” is displayed. You can 

silence the alarm 3 times after which the alarm will not silence until you replace the UV lamp.  

Warning:

 Do not consume water until lamp is replaced

 

RESETTING THE LAMP EXPIRY TIMER:

 After replacing the UV lamp annually, you must re-set the ballast timer 

to clear the “A3” alarm. To do this press and hold the button for approx 10 seconds until “

rSET

” is displayed. 

Release button and the ballast will emit a long beep to confirm reset. Green LED will come on and red LED will turn OFF. 
Display will show “365” again. 

 

 

(G) OPERATION AND MAINTENANCE 

 

Your MEGA8 system is ON continuously during normal use and will continuously supply with safe water.  

Note:

 

Do not try to shut off the UV during short periods of non-use (such as overnight) as repeated ON/OFF cycles can 

shorten the UV lamp and ballast life. 

 

To maintain the optimum disinfection performance of the UV system 

o

 

UV lamp should be replaced when the display reaches “0”. At this point, the UV lamp continues to light but its ability 
to disinfect the water drops below safe limits. Therefore the

 

UV lamp MUST BE REPLACED WHEN THE LAMP 

REPLACEMENT ALARM “A3” COMES ON.

 

o

 

The quartz dome should be cleaned at the time of lamp replacement. If the water quality parameters listed in 
section ‘C’ are exceeded, you should clean and inspect the quartz dome more frequently and clean as necessary. 

o

 

Replace pre-filters every 4-6 months 

 

ITEM 

MODEL 

REPLACEMENT FREQUENCY 

CLEANING 

WHERE TO BUY 

Sediment Pre-filter

 

BC1 or BP5 

4-6 months or when 

pressure across unit drops 

by 10 psi 

 

Major retailers or 
home improvement 
stores or online at 

www.rainfreshstore.ca

 

Carbon Filter 

BC202 

 

UV Lamp 

R830L 

Every 1 year of use 

 

Filter O-Rings 

BH010-3P 

Annually 

 

Quartz Dome 

R830QD 

Every 3 years 

At least during every 
annual lamp change. More 
frequently if water is hard 
or has iron, manganese etc. 

Call Rainfresh or order 
online at 

www.rainfreshstore.ca

 

Dome and Gland 

Nut O-ring 

4032 & 515 

Annually 

 

Included with 
replacement UV 
lamp or dome 

Other parts 

Call Rainfresh or order online at www.rainfreshstore.ca 

GREEN 

LED

 

RED LED

 

DISPLAY

 

BUTTON

 

Содержание MEGA 8

Страница 1: ...rainfresh ca CONTENTS A Introduction 2 B Safety Instructions 2 C Water Quality Requirements 3 D Installation 3 E Disinfection Procedure 6 F Ballast Features 7 G Operation and Maintenance 7 a Winteriz...

Страница 2: ...plug Never pull the cord o Ensure that the lamp connector ground wire is connected to the grounding stud on the chamber during service o Do not touch the lamp or quartz dome by hand Hold the lamp and...

Страница 3: ...h turbidity a back washable sediment filter is recommended as a pre filter We highly recommend a water test to confirm that your water quality is suitable for UV disinfection Rainfresh can test your w...

Страница 4: ...recommended to build a bypass around the system so that you can still have untreated water in the house in case of unit malfunction or if you need to remove the unit for service Fittings Required for...

Страница 5: ...gently rotate the dome while pushing in until it goes past the nut O ring 515 and touches the inside top end of the gland nut See Fig 5 Tip Rotate dome while pushing IN Fig 4 5 6 Carefully slide the q...

Страница 6: ...hlorine and then shut the faucet off Repeat the procedure for all hot and cold outlets in the house Add more bleach as required Run hot faucets longer to allow the chlorine to come through the hot wat...

Страница 7: ...il rSET is displayed Release button and the ballast will emit a long beep to confirm reset Green LED will come on and red LED will turn OFF Display will show 365 again G OPERATION AND MAINTENANCE Your...

Страница 8: ...ff supply valve before the unit and then unplug unit from electrical outlet Open a faucet to depressurize the MEGA8 system and turn off the valve at the outlet port to isolate it WARNING DO NOT LOOK D...

Страница 9: ...s Install a temperature controlled purge valve on the UV outlet UV lamp ends seem burnt after some time This is normal As long as the UV lamp lights a little burn mark at the ends is normal and there...

Страница 10: ...n material or workmanship The Ultraviolet lamp is warranted for a period of thirty 30 days from the date of purchase against defects in materials and workmanship The company s obligation under this wa...

Отзывы: