Installing the MEGA8 unit. 

1.

 

The mounting holes on the MEGA8 unit are 16” apart so that you can mount it directly on to wall studs with 
appropriate screws to carry the weight of the unit. 

Warning:

 

Do not mount the unit directly on drywall without 

appropriate reinforcement.  

2.

 

Install new plumbing using Fig 2 as reference of how the final installation should look.  

3.

 

Carefully unpack UV lamp (R830L) and quartz dome (R830QD). 

Note:

 Hold lamp and dome by the ends with soft, 

dry gloves or cloth. 

The gland nut O-ring (515) is 

in the groove of the gland nut (factory-installed) 
and the dome O-ring (4032) is in a separate 
plastic pack.

 

4.

 

Gently slide the dome O-ring (4032) over the 
top (open end) of the quartz dome to about 1” 
from the open end (Fig 4)

 

5.

 

Gently insert the quartz dome into the gland nut 
(4030) 

and gently rotate the dome while 

pushing in 

until it goes past the nut O-ring (515) 

and touches the inside top end of the gland nut. 
See Fig 5. 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Tip: Rotate dome while pushing IN

  

Fig 4 

6.  Carefully slide the quartz dome with gland nut attached 
into the opening at the top of the UV chamber and 

hand-

tighten

 the gland nut into place. 

CAUTION:

 

 

Do not 

overtighten the gland nut as it can break the quartz 
dome.

 

Note:

 Broken quartz domes are not covered under 

warranty. 

Note:

 Do not use pipe dope or tape on these top threads 

before attaching gland nut 
7.  Slowly open supply-valve and valves before and after 
UV system. 

Check for leaks. Do not proceed to next step 

until leaks are fixed.

 

 

Fig 5 

CORRECT 

Quartz dome is past gland 
nut O-ring (515) and is 
touching the inside top end 
of the gland nut. 

Caution

: Do 

not push hard as it can break 
the quartz dome. 

WRONG 

Quartz dome is not past 
gland nut O-ring (515) 
and is not touching the 
inside top end of the 
gland nut.  

515 

O-Ring 

4032 

O-Ring 

Quartz Dome 

STOP position

 

Содержание MEGA 8

Страница 1: ...rainfresh ca CONTENTS A Introduction 2 B Safety Instructions 2 C Water Quality Requirements 3 D Installation 3 E Disinfection Procedure 6 F Ballast Features 7 G Operation and Maintenance 7 a Winteriz...

Страница 2: ...plug Never pull the cord o Ensure that the lamp connector ground wire is connected to the grounding stud on the chamber during service o Do not touch the lamp or quartz dome by hand Hold the lamp and...

Страница 3: ...h turbidity a back washable sediment filter is recommended as a pre filter We highly recommend a water test to confirm that your water quality is suitable for UV disinfection Rainfresh can test your w...

Страница 4: ...recommended to build a bypass around the system so that you can still have untreated water in the house in case of unit malfunction or if you need to remove the unit for service Fittings Required for...

Страница 5: ...gently rotate the dome while pushing in until it goes past the nut O ring 515 and touches the inside top end of the gland nut See Fig 5 Tip Rotate dome while pushing IN Fig 4 5 6 Carefully slide the q...

Страница 6: ...hlorine and then shut the faucet off Repeat the procedure for all hot and cold outlets in the house Add more bleach as required Run hot faucets longer to allow the chlorine to come through the hot wat...

Страница 7: ...il rSET is displayed Release button and the ballast will emit a long beep to confirm reset Green LED will come on and red LED will turn OFF Display will show 365 again G OPERATION AND MAINTENANCE Your...

Страница 8: ...ff supply valve before the unit and then unplug unit from electrical outlet Open a faucet to depressurize the MEGA8 system and turn off the valve at the outlet port to isolate it WARNING DO NOT LOOK D...

Страница 9: ...s Install a temperature controlled purge valve on the UV outlet UV lamp ends seem burnt after some time This is normal As long as the UV lamp lights a little burn mark at the ends is normal and there...

Страница 10: ...n material or workmanship The Ultraviolet lamp is warranted for a period of thirty 30 days from the date of purchase against defects in materials and workmanship The company s obligation under this wa...

Отзывы: