Rainfresh MEGA 8 Скачать руководство пользователя страница 2

 

(A)

 

INTRODUCTION 

Rainfresh MEGA8 system makes water safe to drink by instantly destroying 
pathogenic bacteria (such as coliforms, E. coli, viruses etc.). It also reduces 
sediment, chlorine, bad tastes and odours. MEGA8 utilizes the proven 
disinfection properties of ultraviolet light (UV) emitted at 254 nm wavelength. 
UV systems are used by many municipalities in Canada and around the world as 
a primary disinfectant as it is a natural, non-chemical, environmentally safe 
technique that does not form any harmful disinfection by-products. 

 

MEGA8 features a 3-stage design. The first stage is a 5 micron sediment filter 
that reduces dirt, rust, sand and other fine particulate matter. The second stage 
is an activated carbon block filter that reduces chlorine, taste and odour by 
>95%. The 3

rd

 and final stage is a UV system that instantly destroys bacteria & 

viruses in the water using germicidal ultraviolet light emitted by a specially 
engineered UV lamp. Treated water flows out of the chamber and is ready for 
consumption. See Fig. 1 

 

 

(B)

 

SAFETY INSTRUCTIONS 

 
 
 
 
 

o

 

WARNING: DO NOT LOOK DIRECTLY AT UV LAMP WHEN LAMP IS ON

UV light can cause serious burns to eyes & skin. 

o

 

WARNING:

 Do not

 

operate the UV lamp outside the UV disinfection chamber. 

o

 

To comply with the National Electrical Code and to provide additional protection from the risk of electric shock, this 
system should only be connected to a properly grounded, grounding-type controller receptacle that is protected by a 
Ground Fault Circuit Interrupter (GFCI).  

o

 

Installation of the UV disinfection system and water filter may interrupt electrical grounding continuity of your plumbing 
system. For directions on restoring the electrical grounding continuity, consult a certified electrician 

o

 

Do not 

operate the system if it has a damaged electrical cord or plug, is malfunctioning, or is damaged in any way. 

o

 

To avoid 

possible electric shock, extra care should be taken since water may be present near electrical equipment. Unless 

specifically referred to in these instructions, do not attempt repairs yourself. 

Do not 

plug the unit in if any electrical 

surfaces or electrical parts are wet. 

o

 

Disconnect power cable from the power outlet by holding the plug. Never pull the cord. 

o

 

Ensure that the lamp connector ground wire is connected to the grounding stud on the chamber during service. 

o

 

Do not touch 

the lamp or quartz dome by hand. Hold the lamp and dome by the ends with soft dry gloves

 

or cloth. 

o

 

WARNING:

 

NEVER INSTALL UNIT BETWEEN YOUR WELL PUMP & PRESSURE TANK

 as that can cause damage to the unit 

and/or your well pump

Always install after your pump and pressure tank (well or lake water) or after your meter and 

your main shut off valve (city water). 

o

 

For use on main cold water line only. 

Do not pass hot water through the unit. 

o

 

Do not 

install in direct sunlight or at a location where the unit may freeze or be subjected to weather elements. 

o

 

Do not 

use this unit for any purpose other than its intended use for potable water filtration and disinfection. The use of 

attachments not recommended, approved or sold by the manufacturer may result in improper performance of the unit or 
an unsafe condition and void the product warranty. 

o

 

Caution:

 

The rubber O-rings provide a water tight seal between the filter head and sump of the pre-filter. It is important 

that they are properly 

seated in the grooves 

of the sump or a water leak could occur. 

o

 

Do not 

over tighten metal fittings into filter INLET or it may crack.  

o

 

Do not 

use torch/heat near filter inlet. If necessary, wrap a wet cloth around the pipe and head to absorb heat. All solder 

joints should be made before joining pipe to the filter head. 

o

 

Do not 

use thread sealing compounds. Use thread seal tape for connections into unit.  

o

 

Caution:

: Do not 

use petroleum based lubricants on the unit as that can damage the unit and cause leaks. Use only food 

grade silicone lubricant available at most retail stores. 

o

 

Before any cleaning or maintenance on the system, always unplug the unit from the power source.  

o

 

Quartz dome and UV lamp is FRAGILE. Handle with extreme care to prevent breakage 

Contains 

mercury 

 

 

UV Lamp contains mercury (Hg).  

•   Dispose or recycle in accordance with applicable laws. 

 

For information on safe handling procedures and safe disposal and recycling, consult :  
https://www.canada.ca/en/environment-climate-change/campaigns/diverting-mercury-light-bulbs.html 
https://www.canada.ca/en/environment-climate-change/services/canadian-environmental-protection-act-
registry/guidelines-objectives-codes-practice/sound-management-lamps-containing-mercury.html#toc12  

 

Fig 1 

Содержание MEGA 8

Страница 1: ...rainfresh ca CONTENTS A Introduction 2 B Safety Instructions 2 C Water Quality Requirements 3 D Installation 3 E Disinfection Procedure 6 F Ballast Features 7 G Operation and Maintenance 7 a Winteriz...

Страница 2: ...plug Never pull the cord o Ensure that the lamp connector ground wire is connected to the grounding stud on the chamber during service o Do not touch the lamp or quartz dome by hand Hold the lamp and...

Страница 3: ...h turbidity a back washable sediment filter is recommended as a pre filter We highly recommend a water test to confirm that your water quality is suitable for UV disinfection Rainfresh can test your w...

Страница 4: ...recommended to build a bypass around the system so that you can still have untreated water in the house in case of unit malfunction or if you need to remove the unit for service Fittings Required for...

Страница 5: ...gently rotate the dome while pushing in until it goes past the nut O ring 515 and touches the inside top end of the gland nut See Fig 5 Tip Rotate dome while pushing IN Fig 4 5 6 Carefully slide the q...

Страница 6: ...hlorine and then shut the faucet off Repeat the procedure for all hot and cold outlets in the house Add more bleach as required Run hot faucets longer to allow the chlorine to come through the hot wat...

Страница 7: ...il rSET is displayed Release button and the ballast will emit a long beep to confirm reset Green LED will come on and red LED will turn OFF Display will show 365 again G OPERATION AND MAINTENANCE Your...

Страница 8: ...ff supply valve before the unit and then unplug unit from electrical outlet Open a faucet to depressurize the MEGA8 system and turn off the valve at the outlet port to isolate it WARNING DO NOT LOOK D...

Страница 9: ...s Install a temperature controlled purge valve on the UV outlet UV lamp ends seem burnt after some time This is normal As long as the UV lamp lights a little burn mark at the ends is normal and there...

Страница 10: ...n material or workmanship The Ultraviolet lamp is warranted for a period of thirty 30 days from the date of purchase against defects in materials and workmanship The company s obligation under this wa...