Rainbow RK-3001-TRREC-N01 Скачать руководство пользователя страница 6

2.4

 

Terminal instructions 

2.4.1

 

Quick test method 

Select  a  suitable  measurement  location,  avoid  rocks,  ensure  that  the  steel 

needle  does  not  touch  hard  objects,  throw  away  the  surface  soil  according  to  the 
required measurement depth, maintain the original tightness of the soil  below, hold 
the  sensor  vertically  and  insert  it  into  the  soil.  Do  not  shake  left  and  right.  It  is 
recommended  to  measure  multiple  times  to  find  the  average  value  within  a  small 
range of a measuring point. 

 

2.4.1 Buried measurement method 

Dig  a  pit  with  a  diameter  of  >20cm  vertically,  insert  the  sensor  needle 

horizontally into the pit wall at a predetermined depth, and fill the pit tightly. After a 
period of stability, measurement and recording can be carried out for several days, 
months or even longer. 

Содержание RK-3001-TRREC-N01

Страница 1: ...Soil Sensor with Portable Handheld Display Terminal RK 3001 TRREC N01 Ver 2 0...

Страница 2: ...urement method 6 Chapter 3 Function and Operation Instructions 7 3 1 Button description 7 3 2 Introduction to the main interface 8 3 3 Operating instructions 9 3 3 1 System setting description 9 3 3 2...

Страница 3: ...Sensor with Portable is widely used in the detection of soil pH dry farming and water saving irrigation precision agriculture forestry geological prospecting plant cultivation water conservancy enviro...

Страница 4: ...code 3001 Soil recorder housing TRREC Soil multi parameter recorder N01 RS485 Modbus RTU protocol air No Bluetooth printing BT Print with Bluetooth not yet developed 1 5 Product selection Product Siz...

Страница 5: ...the push type two in two out wire at the bottom of the connector line The line sequence corresponds to the color brown brown black black yellow yellow blue blue color If multiple soil sensors are con...

Страница 6: ...the sensor vertically and insert it into the soil Do not shake left and right It is recommended to measure multiple times to find the average value within a small range of a measuring point 2 4 1 Buri...

Страница 7: ...e main interface to switch the display interface of different devicesShort press on the menu interface to move the cursor to the left Right direction Short press to the right on the main interface to...

Страница 8: ...turn on or off the recording data When is displayed it means that the recording data is closed 5 buzzer As shown in the figure the buzzer is normally enabled and when the buzzer is disabled it will di...

Страница 9: ...red when the storage is deleted Use the up and down keys to change the time the left and right keys to move the ursor to the next position the cursor finally moves to the confirmation place and lick t...

Страница 10: ...so as not to cause confusion when the configuration software views the data curve 3 3 3 View historical data description In this operation you can view historical data on the device and you can also...

Страница 11: ...ameter will be written to the device This function is to facilitate the modification of individual parameters when other parameters are modified by mistake Set Software version factory default can be...

Страница 12: ...n the Dr Yang recorder configuration software The software will automatically read the Read Device Information and then click Read the Stored Data to import the data stored in the detector into the co...

Страница 13: ...ck Device in the toolbar and click Clear Device Storage Data in the drop down menu to clear the device data After clearing the software prompts Data Clear Successful Chapter 5 Charging Function Descri...

Страница 14: ...cturer for repair circuit failure Please contact the dealer or manufacturer for repair No response when the sensor is inserted circuit failure Please contact the dealer or manufacturer for repair Inac...

Отзывы: