4.3

 

Export data 

Select the export format (TXT/XLS/PDF) in the toolbar to export and save the data to 
the specified path (take PDF as an example), prompting that the export is successful. 

4.4

 

Clear device data 

Click "Device" in the toolbar, and click "Clear Device Storage Data" in the drop-down 
menu  to  clear  the  device  data.  After  clearing,  the  software  prompts  "Data  Clear 
Successful". 

Chapter 5 Charging Function Description 

When the device is turned off, connect the charger to the recorder, and connect 

the other end to the AC220V power supply. After the tester is fully charged, the 
battery is full and it can be used normally. 

Содержание RK-3001-TRREC-N01

Страница 1: ...Soil Sensor with Portable Handheld Display Terminal RK 3001 TRREC N01 Ver 2 0...

Страница 2: ...urement method 6 Chapter 3 Function and Operation Instructions 7 3 1 Button description 7 3 2 Introduction to the main interface 8 3 3 Operating instructions 9 3 3 1 System setting description 9 3 3 2...

Страница 3: ...Sensor with Portable is widely used in the detection of soil pH dry farming and water saving irrigation precision agriculture forestry geological prospecting plant cultivation water conservancy enviro...

Страница 4: ...code 3001 Soil recorder housing TRREC Soil multi parameter recorder N01 RS485 Modbus RTU protocol air No Bluetooth printing BT Print with Bluetooth not yet developed 1 5 Product selection Product Siz...

Страница 5: ...the push type two in two out wire at the bottom of the connector line The line sequence corresponds to the color brown brown black black yellow yellow blue blue color If multiple soil sensors are con...

Страница 6: ...the sensor vertically and insert it into the soil Do not shake left and right It is recommended to measure multiple times to find the average value within a small range of a measuring point 2 4 1 Buri...

Страница 7: ...e main interface to switch the display interface of different devicesShort press on the menu interface to move the cursor to the left Right direction Short press to the right on the main interface to...

Страница 8: ...turn on or off the recording data When is displayed it means that the recording data is closed 5 buzzer As shown in the figure the buzzer is normally enabled and when the buzzer is disabled it will di...

Страница 9: ...red when the storage is deleted Use the up and down keys to change the time the left and right keys to move the ursor to the next position the cursor finally moves to the confirmation place and lick t...

Страница 10: ...so as not to cause confusion when the configuration software views the data curve 3 3 3 View historical data description In this operation you can view historical data on the device and you can also...

Страница 11: ...ameter will be written to the device This function is to facilitate the modification of individual parameters when other parameters are modified by mistake Set Software version factory default can be...

Страница 12: ...n the Dr Yang recorder configuration software The software will automatically read the Read Device Information and then click Read the Stored Data to import the data stored in the detector into the co...

Страница 13: ...ck Device in the toolbar and click Clear Device Storage Data in the drop down menu to clear the device data After clearing the software prompts Data Clear Successful Chapter 5 Charging Function Descri...

Страница 14: ...cturer for repair circuit failure Please contact the dealer or manufacturer for repair No response when the sensor is inserted circuit failure Please contact the dealer or manufacturer for repair Inac...

Отзывы: