background image

Chemigem Installation and Operation

The unit is one of the most advanced pool chemistry controllers of its kind. It is important 

that it is installed and operated in accordance with the instructions provided in this manual. 

The Chemigem is designed to automatically assist in keeping the levels of Chlorine and pH 

correctly balanced in swimming pools and spas. It continuously monitors and adjusts pH and 

Chlorine levels required through state of the art solenoid valves, utilising the natural suction 

of the pool recirculating pump while the pool pump is running adds Chlorine and pool Acid as 

and when required. Stable controlling of the Chlorine and pH levels of the pool water should be 

achieved during the first two weeks of operation. During this period, check the level of Chlorine, 

Total Alkalinity and pH regularly with a good quality test kit to confirm that the unit is keeping to 

the desired levels. The chemical levels are set by the keypads. Once the correct positions have 

been set for the pool water they should remain constant and do not have be changed from 

season to season (however in winter the pool pump running times can be reduced)

Electronic Clock

The in-built electronic clock requires setting to your local time. To set the clock, (Refer to page 

23).

Pool Pump Times

The factory-set pool pump times are on page 23. To change pumping times or to turn the timer 

off,(Refer to pages 22&23).

Pool Water Circulation

To enable the Chemigem to work efficiently, the mixing of the pool water has to be as quick 

and complete as possible. Positioning the return nozzles (eyeballs) to the pool so that the main 

water-body rotates is the best way to achieve this. Under no circumstances should the eyeballs 

be positioned to produce opposing circulation patterns. The unit’s multi-electrode (probe) 

monitors the Chlorine and pH levels as the water travels towards the pump.
If the mixing of the pool water is slow, the multi-electrode (probe) will not receive the signal 

until large amounts of chemicals have been added to the water. When the multi-electrode 

(probe) finally receives the signal, the pool water may be overdosed and the excess warnings 

will operate.

Heated Pool

If the one pool pump is required to service both the pool heating system and the Chemigem, 

the pool heating plumbing must be bypassed. (Refer to pages 12&16)

PREPERATION

ITEMS SUPPLIED

A brief description of the items supplied and the purpose of each item:

Chemigem

The sealed unit is connected to the solenoid valves and assists in keeping the levels of 

Chlorine and pH correctly balanced in swimming pools and spas.

RAINBOW 

POOL

 PRODUCTS 

PTY

 LTD

Содержание CHEMIGEM DM52CHL

Страница 1: ...R A I N B O W P O O L P R O D U C T S P T Y L T D CHEMIGEM DM52CHL Code Description 1 Year Warranty 00052004 Controller for Chlorine only with Chlorine supply controlled by a suction solenoid valve...

Страница 2: ...effectiveness of the chlorine is no longer a guess it is a measured pool water quality parameter that you the user are able to set LIKE AN INDUSTURIAL PROCESS CONTROLLER FOR YOUR POOL Chemigem uses an...

Страница 3: ...INTS BEFORE INSTALLING THE CHEMIGEM WARNING It is important that the Chemigem is installed and operated in accordance with the instructions provided in this manual WARNING There is the risk of electri...

Страница 4: ...als WARNING Ensure the chemical supplies liquid Chlorine and pool Acid are kept in visually different containers to avoid wrong connection Use colour or size differences or both When these two concent...

Страница 5: ...to your local time To set the clock Refer to page 23 Pool Pump Times The factory set pool pump times are on page 23 To change pumping times or to turn the timer off Refer to pages 22 23 Pool Water Cir...

Страница 6: ...rode probe and to provide an injector nozzle for chemicals being dosed into the pool water via the solenoid valves Solenoid Valves The solenoid valves contain the only two moving parts in the Chemigem...

Страница 7: ...e 9 3mm twist drill for metal sheet or wood fixing 10mm drill for making holes in the lids of chemical drums Knife For cutting the plastic tubing to required lengths Screwdriver For affixing self tapp...

Страница 8: ...lse readings from the non moving water and signal warnings until the unit is switched off CHEMIGEM INSTALLATION Position the Chemigem within 3 metres of the tapping band at a convenient height for eas...

Страница 9: ...des of the PVC pipe Ensure the surround to the hole at the O ring contact is smooth and clean Fit the tapping band first checking that the O rings are in position and that the arrow on the tapping ban...

Страница 10: ...connection Use colour or size differences or both Refer to the cutaway diagram of chemical drum on page 12 for a presentation of the following Position the Chlorine and Acid drums in a safe and secure...

Страница 11: ...so as to allow the unit to operate effectively The required suction range is negative 20kPa to negative 70 kPa when the pool pump is running and the filter is clean Methods to obtain improved suction...

Страница 12: ...INSTALLATION DIAGRAM R A I N B O W P O O L P R O D U C T S P T Y L T D...

Страница 13: ...DRILLING TAPPING BAND HOLES TAPPING BAND AND MULTI ELECTRODE PROBE R A I N B O W P O O L P R O D U C T S P T Y L T D...

Страница 14: ...FITTING CHEMIGEM BELOW POOL WATER SURFACE LEVEL FITTING R A I N B O W P O O L P R O D U C T S P T Y L T D...

Страница 15: ...CHEMIGEM WHEN HEATER IS IN CIRCULATION USING VENTURI INJECTOR DEVICE R A I N B O W P O O L P R O D U C T S P T Y L T D...

Страница 16: ...The Chemigem is designed to measure and automatically adjust Chlorine ORP and pH levels in the pool water Refer above As an explanation of what ORP is the following is provided For over 20 years opera...

Страница 17: ...ol over to NEXT Press keypad No 4 Press keypad No 6 again to make DISP flash Press keypad No 4 once more BEFORE STARTING THE CHEMIGEM Before switching on the Chemigem carry out a full water test with...

Страница 18: ...on and off of the pool pump DOSING OF CHEMICALS Dosing of chemicals will only commence after a few minutes to allow for adequate mixing and accurate sensing Similarly the safety warning sounds and ala...

Страница 19: ...irements given by the pool builder Always take samples at a point near the skimmer box for this is where the water is completely mixed giving the most accurate readings never near the pool returns eye...

Страница 20: ...a few times until the screen message states that the pump is operating under AUTOMATIC TIMER Press once more and hold down continuously keypad No 1 until the required ON TIME in hours is displayed on...

Страница 21: ...ll only be necessary to manually dose either Chlorine or pH however if for any reason keyboards No 5 and 6 are both pressed at once only the pH will operate As soon as the manual feed keypad is presse...

Страница 22: ...om the swimming pool pool pump pool filter and associated pool piping for any reason such as when the pool is being serviced During periods of freezing conditions below 32 degrees fahrenheit or zero d...

Страница 23: ...manual feed keypad is pressed the main screen will appear blank for 2 seconds after which it will display which feed is taking place Feeding will continue for about 20 seconds while the keypad is pre...

Страница 24: ...or off manually it will be necessary to use the mains power switch To reinstate the inbuilt pool pump timer set AUTOMATIC PUMP TIMES Refer to page 23 MANUAL STARTING OF THE INBUILT POOL PUMP TIMER It...

Страница 25: ...e START TIME HOURS move the flashing symbol to the right by pressing keypad No 6 The HOURS digits will now be flashing To increase the HOURS press the ENTER keypad once for every hour the start time i...

Страница 26: ...is switched on Refer to Audible Alarm on page 25 The red light will flash at one second intervals When the alarm is sounding and the red light is flashing the unit will also indicate on the screen th...

Страница 27: ...eatedly to get required option Press ESC several times to return to normal display ALARM LIGHT AND SOUND STEPS TO TAKE Alarms must not be ignored Immediately investigate the causes and until it is cer...

Страница 28: ...90 to 300 ppm or 300 mg l STABILISER 30 to 50 ppm or 50 mg l TOTAL ALKALINITY 80 to 300 ppm or 300 mg l TOTAL DlSSOLVED SOLlDS TDS 300 to 1500 ppm or1500 mg l The Chemigem will work at maintaining Chl...

Страница 29: ...ly help keep the correct level of pH and Chlorine in pool water by continuously monitoring the water chemistry while the pool pump is operating Pool Acid and Chlorine is dosed into the pool water as a...

Страница 30: ...hlorine in common use is a sodium hypochlorite solution The Chemigem uses this chemical Diluting Chlorine is strongly recommended as follows Pools larger than 90 000 litres 20 litre drum or larger 20...

Страница 31: ...od on a hot day The Stabiliser level is too low The pH is too high The filter requires backwashing The strainer part of the pump requires cleaning out Inadequate pool water circulation The injector no...

Страница 32: ...dden This is carried out by pressing the ESC keypad No 2 The unit will then dose further pool Acid until the level for pH that was set has been reached High pH levels could be due to the following Ini...

Страница 33: ...R A I N B O W P O O L P R O D U C T S P T Y L T D...

Отзывы: