background image

15" Plus

 –

 Operators Manual

 

Operatos supplemet to

                              Two-16 manual

Содержание 15" Plus

Страница 1: ...15 Plus Operators Manual Operatos supplemet to Two 16 manual...

Страница 2: ...to operate well and reliably it should not be used in humid environments The ambient temperature should not exceed 40 C 104 F or fall below 0 C 32 F Avoid any liquids or metallic items entering the un...

Страница 3: ...be changed from x to the hookwings can be slid off and easily repositioned The table below and over the page gives a full summary of the of luminaires and their Barndoor slide in dimensions 1 2 3 4 5...

Страница 4: ...ature Tape connected to the front side of the filter Tape can be ordered from Rainbow Colour Changers Ensure that sides are parallel and the bottom edge is straight The frames should be taped edge to...

Страница 5: ...espeedusing the Frame selector At the end one of the following will occur If the unit is under trimmed The RCC will stop at full before the filter has been fully loaded on the blue roll Turn the RANGE...

Страница 6: ...the spindle It will also show any noise problems due to badly made scrolls ii Where many units are to run together run the colour changers to 95 and confirm alignment of all units Retrim where necessa...

Страница 7: ...l power supply This can either be a Maxi combined Power Supply Splitter or separate power supply splitter combination Traditionally the PSUs have been rated in terms of the number of 8 RCC units which...

Страница 8: ...changerusingthethreeaddressselectors The gel speed is set by the speed of control input and the Rainbow type The fan is controlled by the standard HI LO fan speed switch on the rear of the Rainbow Inm...

Страница 9: ...longer gel life even lower noise levels and smoother crossfades The speeds of the fans are still controlled by the HI LO switch on the rear of the Rainbow Mode 1 Medium Speed Mode 2 Slow Speed The cro...

Страница 10: ...ade time Mode 3 Address nnn Gel Position nnn 1 Fan Speed Gel speed Max speed Dependent on model no of Frames 15 RCC 4 5s Resolution As DMX 8 Bit Mode 4 Address nn Gel Position nn 1 Fan Speed Gel speed...

Страница 11: ...ily limited on a single fader to avoid all the scrollers jumping from state to state In the same way the fan speeds may be controlled for when total silence is required during a section of a show DMX...

Страница 12: ...peedofgelmovement and fan speeds Each Rainbow uses three independent DMX addresses for control of these features For example Address Position Gel Speed Fan speed 21 21 22 23 24 24 25 26 27 27 28 29 3...

Страница 13: ...ring whilst the Rainbow is only supplied with 24 volt DC power To select this feature simply set the Mode Selector to 8 TIMING OF AUTOMATIC FADES The fade timing is controlled by the Frame switch Set...

Страница 14: ...rtional such 00 Full and FF OFF This can be reversed by a jumper setting on the pcb if needed This is useful if fan levels are to be patched in with light intensity A thermal sensor will override the...

Страница 15: ...c When using speed control the 12 bit fade resolution is only effective if the PlusCard fade time is longer than the control signal fade Where speed control is required from the PlusCard the best resu...

Страница 16: ...evant mode selected in modes 0 to 5 the gel moves at the preset speeds for modes 6 and 7 the inter frame gel speed is controlled by a DMX address Selecting Frame by Frame Mode The 16 position Frame se...

Страница 17: ...ternal and external fan control can be tested by selecting fan levels on the Frames selector Mode A Reserved for Future Development Mode B Self and Functional Tests The PlusCard is fitted with full se...

Страница 18: ...hexadecimal using the Address and Frames switches as follows Address 0 255DEC Most significant 8 bits of level Coarse Frame 0 FHEX Least significant 4 bits of level Fine Selection of Position ADEHEX...

Страница 19: ...Frame selector as follows Address Level Frame Selector Speed 01 01 0 and 4 E Stop nn nn 1 Slow 99 99 2 and F Medium 3 Fast Example Slow movement to 50 Mode F 00 Output for Zero Set Trimming Fades the...

Страница 20: ...alid level is detected move the gel at medium speed until the position equals to the input position from when itwilltracktheinputasperthemode frame andaddresssettings Thiswillgiveasmooth crossfade to...

Страница 21: ...Speed to Quick Flash Fast Fan Speed On Fans Off Modes 3 7 Fans not under control of PlusCard Modes 0 2 Out of Valid Address Range Slow Flash Set address is outside range of 1 512 for DMX 8 s on 8s off...

Страница 22: ...This means that all modes have one extra operating parameter as follows The dowser can be set to default as the last control channel via a hardware jumper on the pcb J23 For furtherinformation on the...

Страница 23: ...GmbH An der Talle 24 28 D 33102 Paderborn Germany Tel 49 0 52 51 14 092 28 Fax 49 0 52 51 14 092 90 www plp international com sales plp international com 2007 Rainbow Colour Changers GmbH Rainbow is a...

Отзывы: