NOTE:
Some controllers do not
provide internal access to the AC
power terminals. In this case a 24 volt
AC adapter is available at your local
sprinkler supply store. You will need
to connect one of the AC adapter
wires to the COM terminal (which
will also have the Black wire from
the SMRT-Y attached) and the other
adapter wire connects to the Orange
wire coming from the SMRT-Y.
3.
Connect the wire or wires you disconnected
from the ‘COM’ terminal to the White wire
from the SMRT-Y cable using a wire nut (see
Figure 9).
4.
Disconnect the target zone wire identified
and marked earlier (zone #1 in figure 10).
Connect it to the Red wire of the SMRT-Y
user interface with a wire nut (see Figure 10).
24V 24V
COM
1
2
3
4
5
6
Figure 9
Figure 10
24V 24V
COM
1
2
3
4
5
6
White
wire
Common wire
Wire
connector
“Hot Wire”
for the sensor
zone