SMRT-Y Soil Moisture Sensor
SMRT-Y User Interface Installation:
Overview
Mount the SMRT-Y user interface on the wall near the controller. Route the SMRT-Y cable to the controller.
Disconnect all wires attached to the common terminal and re-connect them to the White SMRT-Y wire.
!
NOTE:
If there is more than one field common, connect all common wires to the White SMRT-Y
wire.
Connect the Black SMRT-Y wire to the common terminal on the controller. Disconnect the marked zone wire
from its terminal and connect it to the Red SMRT-Y wire. Connect the Green SMRT-Y wire to the terminal
from where the zone wire was removed. Connect the Orange SMRT-Y wire to the 24 volt AC ‘hot spot’ or
transformer terminal (see Figure 8).
Detailed Procedure
1.
Disconnect the wire or wires that are
connected to the “COM” (or Common)
terminal on your controller. Connect the
Black wire from the SMRT-Y user interface to
the controller’s COM terminal (see Figure 7).
Figure 7
24V 24V
COM
1
2
3
4
5
6
Common wire
Black wire
To SMRT-Y