8.2 Start-Up
Connect the pumping system for the water inlet
Make sure that the Operation Conditions (pressure, temperature, flow rate and pH) are in
accordance with the specifications.
Monitor the equipment head loss.
Follow the instructions of the Equipment's Controller Manual.
13
8. OPERATION INSTRUCTIONS
8.1 Before Starting-Up
•
Before operating the equipment, use adequate personal protection (proper clothes, safety
glasses, gloves and other elements of personal protection).
•
Make sure that the flow rate, pressure, temperature and PH are permitted by the equipments
specifications (indicated in the equipment technical data) before starting up. Do not operate
outside of the recommended working conditions.
•
Equipment Pressure: Make sure that the filter is depressurized before opening it.
•
Make sure that all the filters are properly closed to avoid leaks. Do not forget to lock the
safety clip on the clamp. This will prevent accidental opening
•
Make sure that the auxiliary filter key is opened
before starting-up the equipment
•
We recommend the installation of an upstream and downstream valve to isolate the system
during maintenance operations.
1.
Place the correct number of discs on each filter.
2.
Adjust it until the filter base is straight
3.
Install the lid.
4.
Close the clamp.
5.
Check the adjustment of the cap of each filter.
6.
The filter battery is ready to operate.