Impeller Assembly and Shaft Replacement

 

If you are replacing an existing Rain Bird sensor and have already calibrated your flow transmitter, no 
calibration changes are necessary.  For installation of a new flow transmitter or for relocation of a sensor in a 
new pipe size, please refer to the calibration instructions in flow transmitter manual.

 

 

1)  Depressurize pipe from which sensor is to be removed.

 

 

2)  For Insert Style Sensors: Remove the three (3) lock 

nuts that secure the positioning collar to the threaded 
rods of metal sensor. For Tee Type Sensors: Remove 
clevis pin.

 

 

Figure 3

 

Impeller Assembly and Shaft Replacement

 

NOTE DIRECTION OF ARROW

 

 

NOTE: 

Before removing lock nuts, record the dimension 

from top of 

2” NPT adapter to the bottom of the positioning 

collar. This dimension will be required later to reinstall.

 

 

3)  Remove the sensor from the hex adapter or the tee.

 

 

4)  Note the impeller blade orientation relative to flow 

arrows and the alignment hole in metal sensors beside 
one of the sighting holes.  In order to maintain proper 
calibration, the impeller will have to be reinstalled in the 
same manner with the impeller blades pointing toward 
the small alignment hole, and into the flow direction as 
indicated by the flow arrows.

 

 

USE PLIERS HERE

 

 
 
 

NOTE DIRECTION OF 

IMPELLER

 

 
 

 

USE METAL PIN TO 

REMOVE CERAMIC SHAFT

 

 

5)  To remove the old impeller blade assembly, push the old shaft out of the sleeve with the new shaft (or small 

diameter rod) just far enough to grab the end with a pair of pliers and pull the shaft completely out.  The 
impeller assembly will now be free, and will drop out.

 

 

6)  Inspect the shaft and bearings for wear, and replace as necessary.

 

 

7)  Refer to Figure 3. To reinstall, position the impeller in the cavity oriented as in Step 4 so that the impeller 

blades point into the flow direction and toward the small alignment hole located beside one of the sighting 
holes on metal sensors. For Brass Tee Type the flow direction arrow on the top of the sensor housing 
should point downstream with the impeller blades pointing upstream.

 

8)  Carefully push the shaft through the sleeve and impeller, taking care not to damage bearings.  Make sure 

that the shaft is inserted far enough so that it clears the sleeve on each side of the impeller housing. 

NOTE: 

If shaft is not carefully installed, the bearing can be deformed, preventing free rotation.

 

9)  Inspect the O-rings for damage and replace as necessary.  Clean the O-rings and the sleeve and lubricate 

with silicone grease from the packet provided or some other acceptable lubricant.

 

10) Install the sensor into the 

2” NPT adapter or tee so that alignment hole is facing upstream and flow arrows 

point in the direction of the actual flow.  Since the positioning collar was not loosened during this operation, 
the studs should all line up perfectly when the sighting holes are parallel to pipe.  If this has been 
accidentally loosened, please refer to the installation instructions for the alignment of the flow sensor unit.

 

 

11) Install and tighten the nuts or replace the clevis pin.

 

12) For metal sensors, double check that the distance from the top of the 

2” NPT adapter to the bottom of the 

positioning collar equals the dimension as measured in Step 2, and holes in sleeve sight exactly down the 
pipe, the arrows point in direction of flow and alignment holes located beside one sighting hole is pointing 
towards the source.  If not, refer to 

Installation 

section in this manual.

 

13)  This completes the replacement procedure.  The system may now be repressurized and tested.

 

Содержание FS200B

Страница 1: ...wept impeller shape provides higher more constant torque than other impeller designs and is less prone to fouling by water borne debris The forward curved shape coupled with the absence of magnetic dr...

Страница 2: ...nics package inserted into a proprietary cast bronze pipe tee with threaded NPT female iron pipe thread FIPT connections They are available in the following sizes and thread types Model Thread Size FS...

Страница 3: ...ertical pipes 3 Small pipe PVC and Bronze Tee Type sensors are Factory Set but for insert sensors the Insertion depth should be set to 1 1 2 for accurate flow readings The following pages show methods...

Страница 4: ...tlet tee the inside dimension of the tee is not the same as the pipe O D Install the 2 NPT adapter provided using a thread sealant to prevent leakage Tighten as necessary Rain Bird insert style sensor...

Страница 5: ...n data transmission to connect the sensor to the transmitter monitor or controller 3 Make a water tight splice Direct burial silicone grease splices are recommended Rain Bird DBRY20 or 3M DBR Y 6 Two...

Страница 6: ...000 5 4 to 54 20 to 200 1 2 to 12 FS075P 3 4 PVC Tee Flow Sensor 0 1563 0 9000 3 3 to 33 13 to 125 75 to 7 5 FS050P 1 2 PVC Tee Flow Sensor 0 0780 0 9000 1 9 to 19 7 to 70 43 to 4 3 Description of Col...

Страница 7: ...80 2 500 Sch 20 8 625 8 125 41 653 0 283 80 2 500 Sch 30 8 625 8 071 41 063 0 283 80 2 500 Std Wt Sch 40 8 625 7 981 40 086 0 281 80 2 500 Sch 60 8 625 7 813 38 288 0 279 80 2 500 Extra Strong Sch 80...

Страница 8: ...h 30 20 00 19 000 239 666 0 547 400 12 000 Sch 80 20 00 17 938 213 14 0 511 400 12 000 22 Std Wt Sch 20 22 00 21 25 301 975 0 621 500 15 000 Extra Strong Sch 30 22 00 21 00 294 642 0 616 500 15 000 Sc...

Страница 9: ...necessary 7 Refer to Figure 3 To reinstall position the impeller in the cavity oriented as in Step 4 so that the impeller blades point into the flow direction and toward the small alignment hole locat...

Страница 10: ...7 VDC in a No Flow situation or less than 3 VDC in a flow situation disconnect the sensor from the barrier strip and measure the voltage at the sensor input terminals of the barrier strip again It sh...