Installation
Outdoor Model
Mount Controller
Choose a suitable mounting location with access
to an external electrical power source. Allow
clearance for the controller unit’s hinged door
to swing fully open to the left and clearance for
conduit connections below the unit.
Pull open the outer door of the controller and
swing it to the left; then grasp the wiring bay
cover and pull it towards you to remove it.
Drive a mounting screw into the wall. Leave an
1/8 inch gap between the screw head and the
wall surface.
l
b
NOTE:
If necesssary, use the provided anchors
to assure that screws can be tightened securely.
Locate the keyhole slot on back of the controller
unit and hang the unit securely on the mounting
screw.
KEYHOLE
Drive a second mounting screw through the
open hole inside the wiring bay and into the
wall. Verify that the unit is fastened securely to
the wall.
CONNECT
120 VAC
REMOTE
24VAC
ACCESSORY
SENS
1
2
3
4
5
6
7
8
C M
RESET
Connect Power
The ESP-RZXe outdoor controller has an internal
transformer that reduces supply voltage (120 VAC
in U.S. models; 230 VAC in international models; 240
VAC in Australian models) to 24 VAC. You will need to
connect power supply wires to the transformer’s three
wires. (Line, Neutral, Ground).
l
c
WARNING:
Electric shock can cause severe
injury or death. Make sure power supply is
turned OFF before connecting power wires.
l
c
WARNING:
All electrical connections and
wiring runs must comply with local building
codes.
3 IN.
1/8 IN.