ESP-LXIVM Series Controllers
C
At the LEARN FLOW MENU screen, press the Down Arrow key to
select Select Stations, then press Next.
D
A confirmation screen appears; press Next again.
C
LEARN FLOW MENU
Next
Select Stations
All Stations
D
Next
for stations with...
only
Learn Flow will work
E
An information screen appears; press Next again.
F
Press the Arrow keys to navigate the list of stations. Press the Yes
and no keys to set which stations you want to include in the Learn
Flow exercise, then press Next to continue.
B
NOTE: You can choose to run the exercise Now (00:00) or choose
a timed delay of up to 24 hours.
E
Learn Flow
Next
Priority
4. Assigned MV
3. High/Medium/Low
2. Station Runtime
1. Station Address
F
Include in Learn Flow
Next
Sta003
Yes
Yes
No
G
To start the Learn Flow exercise immediately, press Next. Or press
the + and – keys to set a delayed start time. Press the Arrow keys
to navigate between the number setting fields.
H
A confirmation screen appears, confirming the Learn Flow will
overwrite the existing flow rates. Press Start to set the Learn Flow
exercise.
G
Learn Flow
HH:MM
Start Learn Flow In
Next
00
00
:
H
Start
existing learned
overwrite
Learn Flow will
Attention
flow rates
I
The Learn Flow Starting confirmation screen appears, confirming
the time delay until the Learn Flow operation will start.
I
Starting Now
Learn Flow
B
NOTE: An alarm will be posted if one or more stations learn a
flow rate of 0 (zero). Check the valve and 2-Wire Device if you
receive this alarm.
NOTICE
Be sure to Learn Flow again if you make any changes to your
system which affect its hydraulics.