![Rain Bird ESP-LXIVM Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/rain-bird/esp-lxivm-series/esp-lxivm-series_installation-programming-and-operation-manual_3522749022.webp)
22
ESP-LXIVM Series Controllers
Alarm Conditions
Turn the controller dial to AUTO
A
When an alarm condition is present, the Alarm key label will be
present on screen. Press the Alarm key to view alarm details.
B
Any present alarm conditions will then be shown. Press the More
key to continue to the next page.
A
Auto
13 Jan 2018
Sat
06:00
AM
Alarm
B
No Water Days
No Run Times
No Start Times
More Exit
No PGM will AUTO run
B
NOTE: Take the appropriate action to address each alarm condi-
tion. When all alarms have been addressed, the alarm light on
the front panel will no longer be illuminated.
List of Alarm Conditions
Alarm
Condition
No Water Days
There are no water days set in any program.
No Run Times
There are no run times set in any program.
No Start Times
There are no star times set in any program.
No PGM will AUTO
Run
There is no program with start times and run
times and water days.
Max PGMs Stacked
Max is 8 (equal to the start times).
Flow Alarm
Shows for high or low flow conditions. See
"Flow Alarms" on page 63 for more details.
Zero Learned Flow
0 flow is learned for 1 or more stations
FloWatch is turned on. See "Set Flo-Man-
ager®" on page 83 for more details.
No Two-Wire Mod-
ule
2-Wire Module is not enumerated.
Invalid Module
Installed
One or more of the following in is installed:
Triac Module, ESPLX-SM75 Module, FSM
Module, FSCM Module, ESP-LXD-M50 Mod-
ule.
All Addresses are
Zero
There is no address assigned for any of the
four device types.
All paths turned off All 2-Wire paths have been turned off by the
user (remote or at controller).
No AC power
The panel is running on the 9V battery (no
AC).
Duplicate addressee Shows if there are any duplicate addresses
for a Station, MV, Weather, or Flow device.
Shows up to two duplicates.
Device not
responding
Shows if a device is addressed but not
responding to ping.
Shorted paths
One or more paths have been automatically
turned off due a short being detected.