![Rain Bird ESP-LXIVM Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/rain-bird/esp-lxivm-series/esp-lxivm-series_installation-programming-and-operation-manual_3522749029.webp)
29
ESP-LXIVM Series Controllers
C
Press the + and – keys to set the desired Station Address. Press
the Arrow keys to navigate between the number setting fields.
Once all fields are entered, press the Next key.
B
NOTE: An alarm will show if a duplicate 2-Wire Device address
is entered for more than one sensor. See "Alarms" on page 21
for more details.
C
Station Setup
001
STA
Address
Next
1 0 0 0 1
1
Set Priority
Each station can be set to high, medium, low or Non-irrigation.
The controller will run all high priority stations first, then all medium
and finally all low priority, regardless of the station’s program set-
tings.
A
At the Station Setup screen, with Set Priority selected, press Next
to continue.
B
NOTE: Station Priorities are only used when Station Sequenc-
ing is set to Sequence by Station Priority. If you’re using the
default Sequence by Station Numbers, then skip the next
step by pressing Next.
B
Press the + and – keys to select the priority type. Each station can
be set to High, Medium, Low or Non-irrigation.
B
NOTE: Non-irrigation stations such as fountains and land-
scape lighting receive priority to always run, regardless of
weather conditions.
A
Station Setup
001
Set Priority
STA
FloZones
Weather Sensors
Next
B
Station Setup
STA 001
Priority:
High
Done