To do this, follow these instructions:
1. Once the boiler has been removed, locate the smoke unit assembly (see below).
2. Use a phillips head screwdriver to remove the inspection cover screws see below..
3. After removing the inspection cover, inspect the wick. If it is darkly discolored
and hard, it should be replaced.
Replacement parts and wick replacement instructions are available directly from
the M.T.H. Parts Department phone: (order online: www.mth-railking.com, e-mail:
[email protected]; mail: 7020 Columbia Gateway Drive, Columbia MD
21046-1532, FAX: 410-423-0009.
RailKing Coors Light The Silver Bullet
®
Steam Locomotive Set
19
Smoke Unit Location
Remove these five screws
to inspect the Smoke Wick
•
Ensure the lock-down screw is removed during un-packaging
•
Open the reefer door
•
Pull the beer cargo load out using the tab molded into the bottom of the
beer load
•
Remove the filler cap
•
Put in the same amount that you would for an engine (10-15 drops)
•
Put filler cap back on
•
Push beer cargo load all the way to the back of the car. If not pushed al l
the way back it can interfere with the door operation
Close the reefer door
Adding Smoke Fluid (Operating Reefer)
Add Smoke Fluid
Filler Cap
Remove lock-down screw