background image

3

RailKing 2-8-0 Steam Engine

Set Up

There are a few simple steps you must take before operating this RailKing
steamer.

1. You should prime the operating smoke unit with smoke fluid before
operating. Add 15-20 drops of smoke fluid through the smokestack, then
gently blow into the stack to eliminate any air bubbles in the fluid. See Fig. 4
on pg. 10.

2. If you choose not to prime the unit with fluid, turn the smoke unit switch
located under the engine to the OFF position (Fig. 5 on pg 10). Running the
engine without a primed smoke unit may cause damage. See the “ProtoSmoke
Unit Operation” section of this book for more information on smoke unit
maintenance.

3. You should lubricate all side rods and linkage components and pickup
rollers to prevent them from squeaking. Use light household oil and follow the
lubrication points marked “L” in Fig. 2 on p. 8. Do not over-oil. Use only a
drop or two on each pivot point.

4. Put your engine on the track and insert the reverse unit plug that extends out
of the tender into the receptacle at the back of the engine. WARNING: DO
NOT CONNECT THIS ENGINE TO A TENDER FROM ANOTHER
ENGINE; IT MAY CAUSE SERIOUS DAMAGE. Look at the bottom of the
engine and tender where each will have a color-coded stamp. If they match
you may connect those two pieces; if not, don’t.

5. Connect the draw bar between the engine and tender. If there are two holes
in the draw bar, the hole located farthest from the tender is for the minimum
track operation, such as O-31 circles of track. The second hole is for O-72 or
larger operation.

At this point, you are ready to begin running your engine.

Содержание Ready-To-Run 2-8-0

Страница 1: ...contains M T H s Loco Sound sound and train control system The locomotive is easy to operate with any compatible standard AC transformers see the compatibility chart on page 14 and is completely comp...

Страница 2: ...Dispatch 6 Volume Control 7 Maintenance 8 Lubrication and Greasing Instructions 8 Cleaning the Wheels Tires and Track 9 Locomotive Traction Tire Replacement 9 Smoke Unit Maintenance 10 Locomotive Lig...

Страница 3: ...age components and pickup rollers to prevent them from squeaking Use light household oil and follow the lubrication points marked L in Fig 2 on p 8 Do not over oil Use only a drop or two on each pivot...

Страница 4: ...lease the Bell button again The bell will continue to ring from the time your turn it on until you press and release the button again to turn it off Direction Your train is programmed to start in neut...

Страница 5: ...on the run and the engine will maintain the speed you set While the engine is programmed to start with the speed control feature activated you can opt to turn it off This means the engine s speed wil...

Страница 6: ...e CD tape player to connect your microphone to the remote lock on To use Proto Dispatch simply plug the mini cable into the microphone and into the Mic port on the left side of the remote lock on and...

Страница 7: ...the volume of all sounds made by this engine turn the master volume control knob located under the tender clockwise to increase the volume and counter clockwise to decrease the volume see Fig 1 Volum...

Страница 8: ...e locomotive s internal gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first To access the gear box do the follo...

Страница 9: ...oprene rubber traction tires on the rear set of flanged drivers While these tires are extremely durable you may need to replace them at some point 1 Remove the side rods the rods that connect each dri...

Страница 10: ...you choose not to add the fluid or have already added the fluid but choose to run smoke free turn off the smoke unit switch located under the engine body see Fig 5 Failure either to add fluid to the...

Страница 11: ...from the smoke unit s body see Fig 6 After removing the chassis and inspection cover screws lift the inspection plate away and inspect the wick If it is darkly discolored and hard it should be replac...

Страница 12: ...en I press the bell button You may be pressing the button too quickly Try pressing the whistle button more slowly taking approximately one full second to fully depress the button You may be pressing t...

Страница 13: ...knob on the bottom of the chassis counter clockwise to reduce the volume Compatibility This engine will operate on any traditional O 31 or larger O Gauge track system including M T H s RealTrax or Sc...

Страница 14: ...Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Right Terminal Electronic Lionel LW A U 8 18v 75 Watt Standard Lion...

Страница 15: ...plug blades housing output jacks or other parts In the event such conditions exist the train set should not be used untilproperlyrepaired Do not operate your layout unattended Obstructed accessories...

Страница 16: ...t be insured A cover letter including your name address daytime phone number e mail address if available Return Authorization number if required by the service center a copy of your sales receipt and...