RailKing 2-8-0 Steam Engine

• When storing the unit for long periods of time, you may want to add about 15
drops of fluid to prevent the wick from drying out.

• After removing the engine from storage, add another 25 drops of fluid, letting
the wick soak up the fluid for 15 minutes prior to operation.

If you experience poor or no smoke output when the smoke unit is on and has
fluid, check the wick to see if it has become hard, blackened, and unabsorbent
around the heating element. Remove the smoke unit inspection cover from the
smoke unit’s body (see Fig. 6). After removing the chassis and inspection
cover screws, lift the inspection plate away and inspect the wick. If it is darkly
discolored and hard, it should be replaced.

You can obtain replacement wicks and instructions from the M.T.H. Parts
Department.

Locomotive Light Bulb Replacement

To replace the light bulb in the locomotive, follow these instructions and see
the diagrams below:

Remove the locomotive boiler from its chassis as shown in Figure 3 on pg. 8

.

Once the body has been removed, rotate the headlight bulb counter-clockwise
as seen in Figure

7

to remove.

You can obtain replacement bulbs directly from the M.T.H. Parts Department.

Headlight

Figure 7. Replacing the Headlight

Содержание Ready-To-Run 2-8-0

Страница 1: ...contains M T H s Loco Sound sound and train control system The locomotive is easy to operate with any compatible standard AC transformers see the compatibility chart on page 14 and is completely comp...

Страница 2: ...Dispatch 6 Volume Control 7 Maintenance 8 Lubrication and Greasing Instructions 8 Cleaning the Wheels Tires and Track 9 Locomotive Traction Tire Replacement 9 Smoke Unit Maintenance 10 Locomotive Lig...

Страница 3: ...age components and pickup rollers to prevent them from squeaking Use light household oil and follow the lubrication points marked L in Fig 2 on p 8 Do not over oil Use only a drop or two on each pivot...

Страница 4: ...lease the Bell button again The bell will continue to ring from the time your turn it on until you press and release the button again to turn it off Direction Your train is programmed to start in neut...

Страница 5: ...on the run and the engine will maintain the speed you set While the engine is programmed to start with the speed control feature activated you can opt to turn it off This means the engine s speed wil...

Страница 6: ...e CD tape player to connect your microphone to the remote lock on To use Proto Dispatch simply plug the mini cable into the microphone and into the Mic port on the left side of the remote lock on and...

Страница 7: ...the volume of all sounds made by this engine turn the master volume control knob located under the tender clockwise to increase the volume and counter clockwise to decrease the volume see Fig 1 Volum...

Страница 8: ...e locomotive s internal gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first To access the gear box do the follo...

Страница 9: ...oprene rubber traction tires on the rear set of flanged drivers While these tires are extremely durable you may need to replace them at some point 1 Remove the side rods the rods that connect each dri...

Страница 10: ...you choose not to add the fluid or have already added the fluid but choose to run smoke free turn off the smoke unit switch located under the engine body see Fig 5 Failure either to add fluid to the...

Страница 11: ...from the smoke unit s body see Fig 6 After removing the chassis and inspection cover screws lift the inspection plate away and inspect the wick If it is darkly discolored and hard it should be replac...

Страница 12: ...en I press the bell button You may be pressing the button too quickly Try pressing the whistle button more slowly taking approximately one full second to fully depress the button You may be pressing t...

Страница 13: ...knob on the bottom of the chassis counter clockwise to reduce the volume Compatibility This engine will operate on any traditional O 31 or larger O Gauge track system including M T H s RealTrax or Sc...

Страница 14: ...Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Right Terminal Electronic Lionel LW A U 8 18v 75 Watt Standard Lion...

Страница 15: ...plug blades housing output jacks or other parts In the event such conditions exist the train set should not be used untilproperlyrepaired Do not operate your layout unattended Obstructed accessories...

Страница 16: ...t be insured A cover letter including your name address daytime phone number e mail address if available Return Authorization number if required by the service center a copy of your sales receipt and...

Отзывы: