background image

24

RailKing N&W J Steam Engine

Cab Chatter

Lock-out

Volume

Battery

PSA

Remedy

Remedy

Remedy

Remedy

Remedy

Sometimes the Cab Chatter sounds 
don’t play.

I can’t get the engine to run after I 
power up the transformer. It sits still 
with the engine sounds running.

The engine won’t lock into forward, 
neutral, or reverse.

The sounds seem distorted, especially 
when the whistle or bell is activated.

The engine will not leave the initial 
neutral setting

The PSA sounds occasionally repeat 
themselves.

I get no sounds when the engine shifts 
between directions.

After I turn off my transformer, my 
engine continues to make sounds 
before quitting.

Cab Chatter plays only in neutral.

The engine is locked into the neutral 
position. Follow the procedure in the 
“Lock into a Direction” section.

Engine speed must be below 10 scale 
mph (approx. 10 volts or less in 
conventional mode).

Proto-Sound 2.0 volume is set too 
high. Turn the volume control knob on 
the bottom of the chassis counter-

clockwise to reduce the volume.

Check to be sure the battery is 
installed and fully charged. See the 
“Self-Charging Battery Back-Up” 
section.

The battery may be dead or need to 
be charged. See the “Self-Charging 
Battery Back-Up” section.

Proto-Sound 2.0 is designed to 
continue to sound for a few seconds 
after power to the track has been shut 
off.

Proto-Sound 2.0 has a built-in random 
number generator that randomly 
selects each sound clip to play. 
Because there are a limited number of 
sound clips available in each PSA 
sequence, it is probable that some of 
these sound clips will be repeated 
from time to time.

Содержание RAILKING N&W J WITHPROTO-SOUND 2.0READY-TO-RUN TRAIN...

Страница 1: ...ital Command System DCS This new system will allow you to operate your locomotive in Command mode when used with the DCS Remote Control System sold separately or Conventional mode Conventional operati...

Страница 2: ...eration 12 Speed Control 12 Lock into a Direction State 12 Reset to Factory Defaults 13 Automatic Sounds 13 Maintenance Care of Remote Control 14 Lubrication and Greasing Instructions 14 Cleaning the...

Страница 3: ...ck system The quick connectors and built in roadbed allow you to set up RealTrax anywhere including most carpeted surfaces without the need for track nails or the worry of carpet stains Each RealTrax...

Страница 4: ...he lubrication points marked L in Fig 9 on Page 14 Do not over oil Use only a drop or two on each pivot point Priming the Smoke Unit You should prime the smoke unit with smoke fluid before operating A...

Страница 5: ...own on the small finger that extends from under the right side of the coupler to open the coupler knuckle and allow the couplers to interlock as shown in Figure 6 Insert the reverse unit plug that ext...

Страница 6: ...anufacturer s engines Because the RailKing remote is an infrared line of sight remote you must aim it at the lock on in order to send signals to the track The green LED atop the lock on will come on i...

Страница 7: ...r as long as you continue to depress the button It will stop when you release the button B ell To sound the bell firmly press and release the Bell button To turn the bell off press and release the Bel...

Страница 8: ...sounds made by this engine turn the master volume control knob located under the tender clockwise to increase the volume and counter clockwise to decrease the volume see Fig 8 Proto Sound 2 0 VolumeAd...

Страница 9: ...hould read these instructions thoroughly before using Proto Sound 2 0 features in order to prevent harm to yourself or your equipment Activating Proto Sound 2 0 Conventional Mode Features Proto Sound...

Страница 10: ...ce of PSA The reverse unit is temporarily disabled so that the train will not move as you use the Direction button to trigger the sounds and Proto Sound 2 0 has disabled operator control over the Whis...

Страница 11: ...e engine to run the PSA Otherwise the engine without PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automatically disabled during the PSA cycle If th...

Страница 12: ...turn it off This means the engine s speed will fall as it labors up a hill and increase as it travels downward It is also affected by the addition or releasing of cars while on the run To turn speed...

Страница 13: ...ned to the engine and reset it to its factory defaults while in Neutral press the Whistle button once followed immediately by five quick pushes of the Bell button Two horn blasts will indicate that th...

Страница 14: ...g for extended periods Do not drop the remote It can damage the delicate electronics inside Lubrication and Greasing Instructions The engine should be oiled and greased in order to run properly You sh...

Страница 15: ...located at the fourth set of drivers counting from the front of the engine 3 Use a grease tube dispenser to put a small amount approx 1 2 ml of lithium based grease into the gearbox 4 Replace the scre...

Страница 16: ...ction Tire Replacement Instructions Your locomotive is equipped with two neoprene rubber traction tires on the rear set of flanged drivers While these tires are extremely durable you may need to repla...

Страница 17: ...e turn off the smoke unit switch located under the body see figure 5 on pg 5 Failure either to add fluid to the unit or to turn it off may damage the smoke unit heating element and or wicking material...

Страница 18: ...er from its chassis as shown in Figure 10 Once the body has been removed rotate the headlight bulb counter clockwise as seen in Figure 12 to remove You can obtain replacement bulbs directly from the M...

Страница 19: ...body and chassis see Figure 13 2 You may need to twist the car a little to make to roof come loose from the body 3 Gently pull the bulb away from its housing see Figure 13 3 and push the replacement b...

Страница 20: ...engine in neutral and leave the track voltage at 12 volts for 15 minutes If the garbled or distorted sounds are reduced the battery charge has run down and can be recharged Do this by leaving the eng...

Страница 21: ...eater than 256 colors The CD will not work on a Mac OS unless you run VirtualPC Running RR Track Software You may run the RR Track software directly off of the CD Rom or you may install the software t...

Страница 22: ...hat says My Computer 2 Find your CD Rom drive 3 With the MTH CD Rom in the drive double click on the icon for the CD Rom drive 4 Find the folder on the CD Rom entitled INSTALLATION 5 Choose the folder...

Страница 23: ...ring when I press the bell button When I try to fire the coupler PSA starts The Proto Coupler won t let the engine uncouple on the fly You may be pressing the button too quickly Try pressing the whis...

Страница 24: ...ked into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is s...

Страница 25: ...int After approximately 12 rings of the bell it will automatically turn off Because PSA must control various effects in each sequence Proto Sound 2 0 takes control of these sound effects until you exi...

Страница 26: ...tandard Lionel1053 U A 8 17v 60 Watt Standard Lionel1063 U A 8 17v 60 Watt Standard All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Left Terminal Right Terminal Electron...

Страница 27: ...ols how much smoke each engine outputs and matches smoke to locomotive speed Locomotive Lighting Control Independently controls locomotive headlights marker and interior lights and ditch lights Emerge...

Страница 28: ...etermine locomotive values for consist make ups allowing multiple locomotives belonging to a consist to operate together Query Locomotive Information User can query locomotive programming to learn loc...

Страница 29: ...ayout unattended Obstructed accessories or stalled trains may overheat resulting in damage to your layout This train set is intended for indoor use Do not use if water is present Serious injury or fat...

Страница 30: ..._____________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ______...

Страница 31: ..._____________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ______...

Страница 32: ...ns when contacting M T H for your Return Authorization number 3 Please make sure you have followed the instructions carefully before returning any merchandise for service Limited One Year Warranty All...

Отзывы: