background image

Proto-Sound 2.0 Operating Instructions 

This manual contains the operating instructions for Proto-Sound 2.0 in 
conventional mode only.  Instructions for accessing DCS command mode features 
accompany the DCS Remote Control System equipment.

Activating Proto-Sound 2.0 Conventional Mode Features

Proto-Sound 2.0 features are activated by sequences of Bell a nd Horn button 
pushes described below.  Please read the full descriptions of  each feature before 
using it. To use these buttons to activate features rather than to blow the horn or 
ring the bell, you should tap the buttons very quickly with a ½-second pause 
between button presses.  You may need to practice your timing to make this work 
smoothly.

Rail King 4-6-6-4 Challenger

7

Timing Chart

Total Time Lapse: 1

Seconds

½

Press

Horn

Short & 

Firm

½ Sec.

Pause

½ Sec.

Pause

Press

Bell

Short & 

Firm

Press

Bell

Short & 

Firm

Freight Yard Sounds (FYS) or 
Passenger Station Announcements (PSA): 

Your engine is equipped with a sound package of either freight yard or passenger station 
sounds that you can play.  

Each sequence described below will play as long as it is left 

on, randomly generating sounds, but be sure to allow approximately 30 seconds 
between the button pushes described below to allow the FYS/PSA sufficient time to 
run through each sequence.

!

To cue the sound system to play the FYS/PSA, quickly but firmly tap the Bell button 
once followed by 2 quick taps of the 

Horn/Whistle button while the engine is moving.  

Tap the buttons quickly but allow approximately ½ second between each press.  

!

Press the Direction button once to stop the engine.  This will trigger the first sequence 
of  FYS/PSA. The reverse unit is temporarily disabled so that the train will not move as 
you use the Direction button to trigger the sounds, and Proto-Sound 2.0 has disabled 
operator control over the 

Horn/Whistle and Bell buttons until the full FYS/PSA 

sequence is complete.

!

After waiting about 30 seconds for that sequence to run, press the Direction button 
again to trigger the second sequence of  FYS/PSA. 

!

After about 30 seconds, press the Direction button again to trigger the third FYS/PSA 
sequence.  

!

Again, after allowing about 30 seconds for that sequence to run, press the Direction 

Feature to Be Activated:

Freight Yard Sounds/Passenger Station Announcement
Fire the Rear Coupler
Fire the Front Coupler
Speed Control On/Off
Lock into a Direction/Unlock
Reset to Factory Defaults

Button Code:

1 Bell, 2 Whistle/Horn
1 Bell, 3 Whistle/Horn
1 Bell, 4 Whistle/Horn
1 Whistle/Horn, 2 Bells 

(From Neutral Only)

1 Whistle/Horn, 3 Bells
1 Whistle/Horn, 5 Bells 

(From Neutral Only)

Содержание 4-6-6-4 Challenger

Страница 1: ...Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 19 for a complete list of compatible transform...

Страница 2: ...s 10 16 As with all electric products precautions should be observed during handling and use to reduce the risk of electric shock WARNING When using electrical products basic safety precautions should...

Страница 3: ...e recommend M T H ProtoSmoke Seuthe LGB or LVTS fluids Do not overfill the unit or the fluid may leak out and coat the interior engine components Figure 2 NOTE Smoke Unit Switch is now a volume pot ty...

Страница 4: ...CT THIS ENGINE TO A TENDER FROM ANOTHER ENGINE IT MAY CAUSE SERIOUS DAMAGE Connect the draw bar between the engine and tender The draw bar hole located farthest from the tender is for applications suc...

Страница 5: ...ine will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and rel...

Страница 6: ...all sounds made by this engine turn the master volume control knob located next to the fuel tank clockwise to increase the volume and counter clockwise to decrease the volume Proto Sound 2 0 Volume A...

Страница 7: ...on pushes described below to allow the FYS PSA sufficient time to run through each sequence To cue the sound system to play the FYS PSA quickly but firmly tap the Bell button once followed by 2 quick...

Страница 8: ...nce you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automatically disa...

Страница 9: ...n quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn whistle...

Страница 10: ...sts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any tim...

Страница 11: ...2 First remove the six body mount screws to separate the chassis from the boiler and tender shell Four of the screws in the engine are located through holes in the drive blocks Truck may need to be mo...

Страница 12: ...To clean the track use RailKing Track Cleaning Fluid or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that...

Страница 13: ...will wobble while operating 5 Make sure the tire is fully seated inside the groove Use a razor blade to trim away any excess tire that doesn t seat itself inside the groove properly 6 Reinstall the s...

Страница 14: ...remove the light bulb from the headlight shell 5 Gently push the new light bulb into the headlight housing 6 Reconnect the blue connectors 7 Reassemble pilot and headlight shell Marker LEDs The marker...

Страница 15: ...nterior Light 1 Unplug the black connector at the rear of the boiler shell See fig 8a 2 Gently pull on the wires to remove the light bulb from the backhead 3 Gently push the new light bulb into the ba...

Страница 16: ...If the sounds are improved at the end of the 15 minute test charge the battery charge has run down and can be recharged There are a number of Leave the engine in neutral with track voltage at 10 12 vo...

Страница 17: ...oat the interior engine components If you choose not to add the fluid or have already added the fluid but choose to run smoke free turn off the smoke unit switch located under the tender body see figu...

Страница 18: ...Inspection Cover Screws Figure 15 Figure 14 Remove Screws to separate the boiler Rail King 4 6 6 4 Challenger 18...

Страница 19: ...ll won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled When I press the...

Страница 20: ...to the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is set too...

Страница 21: ...realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS PSA...

Страница 22: ...d Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v...

Страница 23: ...utton push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions including so...

Страница 24: ...less of whether you discussed the problem with a service technician when contacting the Service Center for your Return Authorization Please make sure you have followed the instructions carefully befor...

Отзывы: