4. After removing the failed hard drive and replacing with a new hard drive, if the hard drive
is properly installed, the LCD display screen will display the following messages:
5. After few seconds of installing the new hard drive, the LCD display screen will display the
data rebuilding progress:
Pri->Sec represents that the data in the original hard drive (primary hard drive) is copied
to the new hard drive (secondary hard drive). XXX % represents the rebuilding completion
percentage.
6. When the rebuilding is fully completed, the LCD display screen will again display the
following messages:
7. When SR2611 is overheating, “T” will be displayed on the lower right-hand corner of
screen (As shown in illustration)
8. When cooling fan module is not functional, “F” will be displayed on the upper right-hand
corner of screen. (As shown in illustration)
10
Hard Disk status on LCD screen