889-1600-04
Model P-1400 Operations Manual Rev Apr 2020 Page
19
of 33
5.2.1
PRIMARY VITAL OUTPUT MAPPING SCREENS
P
ARAMETER
...................Primary Vital Output Mapping.
S
ETTINGS
........................32 selections - any and all combinations of the four Loop Status
Inputs and the Vital Input.
S
ETTING
D
ISPLAYED
......Bargraph indicates Loop Status Inputs and/or Vital Input
mapped to the Primary Vital Output. In Loop Status Input
mode, the leftmost segment = Loop Status Input 4, next
segment = Loop Status Input 3, next segment = Loop Status
Input 2, next segment = Loop Status Input 1. In Vital Input
mode, the sixth segment from left = Vital Input.
7
S
EGMENT
D
ISPLAY
......7-segment display will show currently selected setting. The
first character corresponds to the Loop Status Inputs mapped to
the Primary Vital Output, the second character corresponds to
the Vital Input mapped to the Primary Vital Output.
D
EFAULT
S
ETTING
..........00. No Loop Status Inputs mapped to the Primary Vital Output.
Vital Input not mapped to the Primary Vital Output.
E
XAMPLE
........................Loop Status Inputs 1, 2, & 3 mapped to the Primary Vital
Output. Vital Input not mapped to the Primary Vital Output.
N
OTES
.............................The first character is displayed in Hexadecimal notation (Base
16).
To set the mapping status of the Loop Status Inputs, repeatedly press the
FUNC
pushbutton to enter Program
Mode and toggle through the set-up parameters until the display screen shows the bargraph and two of the seven
segment display characters. The left character will flash indicating the current setting and the four leftmost
bargraph segments will show the corresponding Loop Status Input mapping. Use the
(UP) or
(DOWN)
pushbutton to change the setting to the desired configuration. The various combinations of display characters and
bargraph display are shown below.
©
Any Input on Loops 3, 2, or 1 will be mapped
to the Primary Vital Output.
Any Input on Loops 3 or 2 will be mapped to
the Vital Output.
Any Input on Loops 3 or 1 will be mapped to
the Primary Vital Output.
Any Input on Loop 3 will be mapped to the
Primary Vital Output.
Any Input on Loops 2 or 1 will be mapped to
the Primary Vital Output.
Any Input on Loop 2 will be mapped to the
Primary Vital Output.
Any Input on Loop 1 will be mapped to the
Primary Vital Output.
No Loop Inputs will be mapped to the Primary
Vital Output.
Display Setting
Loop Status Inputs Selected
Any Input on Loops 4, 3, 2, or 1 will be
mapped to the Primary Vital Output.
Any Input on Loops 4, 3, or 2 will be mapped
to the Primary Vital Output.
Any Input on Loops 4, 3, or 1 will be mapped
to the Primary Vital Output.
Any Input on Loops 4 or 3 will be mapped to
the Primary Vital Output.
Any Input on Loops 4, 2, or 1 will be mapped
to the Primary Vital Output.
Any Input on Loops 4 or 2 will be mapped to
the Primary Vital Output.
Any Input on Loops 4 or 1 will be mapped to
the Primary Vital Output.
Any Input on Loop 4 will be mapped to the
Primary Vital Output.
3
4
1
2