889-1600-04
Model P-1400 Operations Manual Rev Apr 2020 Page
18
of 33
P
ARAMETER
...................Option 10 (Inverted Vital Output).
S
ETTINGS
........................ON or OFF.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........OFF for all loop inputs.
E
XAMPLE
........................Option 10 is turned OFF.
N
OTES
.............................This option is a detector-wide setting. Changing it for one loop
input changes it for all loop inputs.
P
ARAMETER
...................Primary Vital Output Delay.
S
ETTINGS
........................256 selections - 00.0 to 25.5 Seconds in 0.1 second steps.
S
ETTING
D
ISPLAYED
......7-segment display will show currently selected setting.
7
S
EGMENT
D
ISPLAY
......Currently selected Delay time in seconds.
D
EFAULT
S
ETTING
..........00.0 seconds.
E
XAMPLE
........................Delay of 10 seconds selected for the Primary Vital Output.
N
OTES
.............................If the loop input’s detection zone is occupied when this
parameter is changed, it will not take effect until the detection
zone is empty or the loop input is reset.
P
ARAMETER
...................Primary Vital Output Extension.
S
ETTINGS
........................256 selections - 00.0 to 25.5 Seconds in 0.1 second steps.
S
ETTING
D
ISPLAYED
......7-segment display will show currently selected setting.
7
S
EGMENT
D
ISPLAY
......Currently selected Extension time in seconds.
D
EFAULT
S
ETTING
..........00.0 seconds.
E
XAMPLE
........................Extension of 2.5 seconds selected for the Primary Vital Output.
N
OTES
.............................If the loop input’s detection zone is occupied when this
parameter is changed, it will not take effect until the detection
zone is empty or the loop input is reset.
P
ARAMETER
...................Loop Fail.
S
ETTINGS
........................Pressing the
(UP) or
(DOWN) pushbutton will clear the
Loop Fail memory.
S
ETTING
D
ISPLAYED
......View only.
7
S
EGMENT
D
ISPLAY
......Loop Failures since the last time it was cleared manually or due
to power failure.
D
EFAULT
S
ETTING
..........000.
E
XAMPLE
........................There are 8 Loop Failures in the accumulator for channel 1.
N
OTES
.............................Count will be reset to 0 after loss of power, pressing the
(UP) or
(DOWN) pushbutton, or a reset input to the Reset
terminal on the motherboard.
P
ARAMETER
........................Firmware Version and Revision.
S
ETTINGS
.............................View Only.
S
ETTING
D
ISPLAYED
...........View Only.
7
S
EGMENT
D
ISPLAY
...........Model letter and firmware version on one
screen and firmware revision on the other
screen. The display will toggle between
the two screens with a 50% duty cycle.
D
EFAULT
S
ETTING
...............Not Applicable.
E
XAMPLE
.............................Model P-1400 firmware version 3,
revision .00.
EXTENSION
SECONDS
©
DELAY
SECONDS
©
LOOP FAIL
1
©
©
1
©
OPTION
OFF
1
©