RAE PowerPak User’s Guide
18
11
Connection
Note:
The following steps must be performed outside the
hazardous area or with a “hot zone” permit.
Now connect the cable between the RAE PowerPak and the
MeshGuard.
With the MeshGuard or MeshGuard LEL securely in its housing, you can
remove the cover over the battery compartment so that you can replace
the internal battery in the MeshGuard. Use the sensor and battery
removal tool as shown.
The connector from the RAE PowerPak screws into the MeshGuard’s
battery compartment. Bottom views of the MeshGuard in its steel
enclosure are shown in the procedure below.
1. Remove battery cover with the 3-pin end of the sensor and battery
removal tool by turning counterclockwise.
2. Lift off the cover.
3. Insert the power end of the cable
connected to the Power Pack.
Sensor and battery
removal tool
(P/N 019-2044-000)
Power end
of cable