MIB Parameters
Appendix F
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3
F-6
winlink1000OduAdmHostsPort
1.3.6.1.4.1.4458.1000.1.1.12.1.3
Integer
RW UDP port of the trap destination. A change is
effective immediately.
winlink1000OduBuzzerAdminState
1.3.6.1.4.1.4458.1000.1.1.13
Integer
RW This parameter controls the activation of the
buzzer while the unit is in install mode. A change is
effective immediately. The valid values are:
disabled (0) enabled (1).
winlink1000OduProductId
1.3.6.1.4.1.4458.1000.1.1.14
DisplayString
RO
This parameter is reserved for the Manager
application provided with the product.
winlink1000OduReadCommunity
1.3.6.1.4.1.4458.1000.1.1.15
DisplayString
RW Read Community String. This parameter always
returns ***** when retrieving its value. It is used by
the Manager application to change the Read
Community String. The SNMP agent accepts only
encrypted values.
winlink1000OduReadWriteCommunity
1.3.6.1.4.1.4458.1000.1.1.16
DisplayString
RW Read/Write Community String. This parameter
always returns ***** when retrieving its value. It is
used by the Manager application to change the
Read/Write Community String. The SNMP agent
accepts only encrypted values.
winlink1000OduTrapCommunity
1.3.6.1.4.1.4458.1000.1.1.17
DisplayString
RW Trap Community String. This parameter is used by
the Manager application to change the Trap
Community String. The SNMP agent accepts only
encrypted values.
winlink1000OduAdmSnmpAgentVersion
1.3.6.1.4.1.4458.1000.1.1.18
Integer
RO
Major version of the SNMP agent.
winlink1000OduAdmRemoteSiteName
1.3.6.1.4.1.4458.1000.1.1.19
DisplayString
RO
Remote site name. Returns the same value as
sysLocation parameter of the remote site.
winlink1000OduAdmSnmpAgentMinorVe
rsion
1.3.6.1.4.1.4458.1000.1.1.20
Integer
RO
Minor version of the SNMP agent.
winlink1000OduAdmLinkPassword
1.3.6.1.4.1.4458.1000.1.1.21
DisplayString
RW Link Password. This parameter always returns
***** when retrieving its value. It is used by the
Manager application to change the Link Password.
The SNMP agent accepts only encrypted values.
winlink1000OduAdmSiteLinkPassword
1.3.6.1.4.1.4458.1000.1.1.22
DisplayString
RW Site Link Password. This parameter always returns
***** when retrieving its value. It is used by the
Manager application to change the Link Password
of the site. The SNMP agent accepts only
encrypted values.
winlink1000OduAdmDefaultPassword
1.3.6.1.4.1.4458.1000.1.1.23
Integer
RO
This parameter indicates if the current Link
Password is the default password.
winlink1000OduAdmConnectionType
1.3.6.1.4.1.4458.1000.1.1.24
Integer
RO
This parameter indicates if the Manager
application is connected to the local ODU or to the
remote ODU over the air. A value of 'unknown'
indicates community string mismatch.
winlink1000OduAdmBackToFactorySetti
ngsCmd
1.3.6.1.4.1.4458.1000.1.1.25
Integer
RW Back to factory settings Command. A change is
effective after reset. The read value is always 0.
winlink1000OduAdmIpParamsCnfg
1.3.6.1.4.1.4458.1000.1.1.26
DisplayString
RW ODU IP address Configuration. The format is:
<IP_Address>|<Subnet_Mask>|<Default_Gatewa
y>|
winlink1000OduAdmVlanID
1.3.6.1.4.1.4458.1000.1.1.27
Integer
RW VLAN ID. Valid values are 1 to 4094. Initial value is
0 meaning VLAN unaware.
winlink1000OduAdmVlanPriority
1.3.6.1.4.1.4458.1000.1.1.28
Integer
RW VLAN Priority. 0 is lowest priority 7 is highest
priority.
winlink1000OduAdmSN
1.3.6.1.4.1.4458.1000.1.1.29
DisplayString
RO
IDU Serial Number
winlink1000OduSrvMode
1.3.6.1.4.1.4458.1000.1.2.1
Integer
RW System mode. The only value that can be set is
installMode; normalMode reserved to the Manager
application provided with the product. A change is
effective after link re-synchronization.
Table F-2: Private MIB Parameters (Sheet 2 of 14)
Name
OID
Type
Access
Description