background image

 

16 

 

7.1.2. Platform Scales: HX7.4.xx.C, HX7.4.xx.H, HX7.4.xx.H/Z Series 

 

  Take the device out of the packaging (pallet).  

  Place  the  device  on  a  flat  and  even  surface.  Keep  it  far  away  from  any 

sources of heat. 

  Remove transport locks (if installed): 

 

 

 

  Fix the feet (if not installed): 

 
 

7.1.3. Ramp Scales: HX7.4N Series 

 

  Take the device out of the packaging (pallet).  

  Prior  to  installation,  mount  a  steel  bracket  (2)  onto  a  foot  base  (1),  do  it 

using  an  expanding  ring  (3),  next  screw  the  foot  base  (1)  onto  a foot  pin 
(4). 

 

 

 

  Place the scale on an even surface, install ramps onto the steel brackets.  

  Remove  ramps,  looking  through  bracket  holes,  mark  spots  where 

openings for anchor bolts are to be made.  

  Drill openings, mount steel brackets to the ground. 

 

 

Содержание HX7

Страница 1: ......

Страница 2: ...2 JULY 2020...

Страница 3: ...ately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery discharge in case of prolonged storage of the de...

Страница 4: ...unctional Scales 15 7 1 2 Platform Scales HX7 4 xx C HX7 4 xx H HX7 4 xx H Z Series 16 7 1 3 Ramp Scales HX7 4N Series 16 7 1 4 Track Scales HX7 2K Series 17 7 2 Levelling 1 Load Cell Platform Scales...

Страница 5: ...ed to repair or exchange all elements that appear to be faulty by production or by construction B Defining defects of unclear origin and means of their elimination can only be realized with the assist...

Страница 6: ...tton You can use a solution of water and detergent soap dishwashing detergent glass cleaner Gently rub the cleaned surface and let it dry Repeat the cleaning process if needed In the case of hard to r...

Страница 7: ...cators of all scales feature stainless steel housings polyester overlay and polyamide glands Platforms of both livestock and ramp scales their load bearing structures and weighing tracks can be water...

Страница 8: ...ce directly In case of any problems with correct operation of the scale contact the closest manufacturer s service point In case of defects deliver the faulty product to the manufacturer s service poi...

Страница 9: ...oated steel 1 load cell scale design the main components 1 load cell scale design the main components 1 weighing pan 2 cross 3 load cell 4 base 6 2 Multiple Load Cell Scales Multiple load cell HX7 sca...

Страница 10: ...7 scale with load cell modules is intended to carry out mass measurement of silos Modules are built into construction of ground fixed silo s support In most cases the scale design includes 3 4 load ce...

Страница 11: ...tor option 4 RS232 M12 8P connector 5 RS232 M12 8P connector option 6 RS232 M12 8P connector option 7 RS485 M12 8P connector option 8 Cable gland for a cable of a weighing platform 1 9 Cable gland for...

Страница 12: ...in5 GND Pin6 GND Pin7 24VDC Pin8 24VDC 4INPUTS Pin1 OUT1 Pin2 OUT2 Pin3 WY3 Pin4 OUT4 Pin5 COM Pin6 24VDC Pin7 GND Pin8 NC 4OUTPUTS Pin1 IN1 Pin2 IN2 Pin3 IN3 Pin4 IN4 Pin5 COM Pin6 24VDC Pin7 GND Pin...

Страница 13: ...inputs and 12 outputs It is equipped with optoisolated inputs and semiconductor outputs and enables free configuration of both the inputs and outputs using indicator menu For 12IN 12OUT module the ind...

Страница 14: ...6 7 2 I O Schematic Diagrams 4 inputs 4 outputs 6 8 Operation Panel Keys Press to switch the device on off Press to enter the main menu Press to log in Press to cancel the message Press to zero the sc...

Страница 15: ...Programmable key assigned to an on screen button Programmable key assigned to an on screen button Programmable key assigned to an on screen button Programmable key assigned to an on screen button 7 S...

Страница 16: ...installed 7 1 3 Ramp Scales HX7 4N Series Take the device out of the packaging pallet Prior to installation mount a steel bracket 2 onto a foot base 1 do it using an expanding ring 3 next screw the f...

Страница 17: ...on must be paid to stresses and the weighing system i e the weighing system must lack the stresses 7 2 Levelling 1 Load Cell Platform Scales It is necessary to level the scale do it by turning its fee...

Страница 18: ...splayed continuously battery charged within 75 100 range of permissible voltage pictogram displayed continuously battery charged within 50 75 range of permissible voltage pictogram displayed continuou...

Страница 19: ...re the home screen is to be found in PUE HX7 indicator software manual 8 1 Top Bar The top bar displays the following information Working mode name and symbol Device name Wireless communication on Com...

Страница 20: ...n customize the screen 8 4 Pictograms The pictograms assigned to operation panel keys are to be found underneath the workspace You can define on screen pictograms individually for each working mode 9...

Страница 21: ...when editing numeric and text values Press to select change working mode Press to confirm accept modifications Press to go back or to discard entering parameter modifications Press to go up the menu o...

Страница 22: ...ntout template universal variable value etc Button functions change depending on the edit box type 9 3 1 Numerical Box Where Digit mode To change keyboard working mode press key Keyboard working mode...

Страница 23: ...it 6 Press to enter digit 7 Press to enter digit 8 Press to enter digit 9 Press to enter digit 0 Press to enter dot hold the key for a few seconds Press to delete one character Press to exit the edit...

Страница 24: ...Press to enter Press to enter a b c Press to move the cursor to the left long press Press to enter d e f Press to move the cursor up long press Press to enter g h i Press to move the cursor to the rig...

Страница 25: ...tic for a particular interface language are automatically added to the table when the given language gets selected Diacritical sign table Polish Diacritical sign table English German French Spanish Wh...

Страница 26: ...e weighing pan Read the result when stability marker is displayed 10 1 Operation conditions for 1 load cell scales To assure long term operation and correct mass measurements follow the rules presente...

Страница 27: ...ced on the scale must remain unsupported ramp scales trucks used in meat plants it is necessary to select platform matching the span of truck casters this is to make sure that in case of trucks of wei...

Страница 28: ...28 11 DIAGRAMS OF CONNECTION CABLES Indicator computer cable Indicator printer cable EPSON...

Страница 29: ...29 Indicator printer cable ZEBRA Indicator IN OUT cable Indicator barcode scanner cable LS2208...

Страница 30: ...P cable Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends 12 TECHNICAL SPECIFICATION For technical specifications of respective scales go to RADWAG website...

Страница 31: ...31...

Отзывы: