These  are  much  more  resistant  to  long-lasting  harsh  conditions  typical  for 
slaughterhouses and livestock purchase sites. Powder-coated livestock scales 
can be used for rare small volume production, they must be stored clean in dry 
storage area and can be washed using water with a detergent. Do not use any 
agents  or  cleansers  that  are  not  intended  to  come  into  contact  with  skin  (i.e. 
requiring use of protecting gloves). 

 

In  case  of track  scales  it is forbidden  to  use  chemicals  containing  penetrating 
substances.  Grease  and  impurities  accumulating  in  places  where  the  scale 
track touches the line track must be cleaned off periodically. 

 

Weighing  indicators  of  all  scales  feature  stainless  steel  housings,  polyester 
overlay  and  polyamide  glands.  Platforms  of  both  livestock  and  ramp  scales, 
their load-bearing structures and weighing tracks can be water-jet cleaned, the 
water  temperature  must  be  up  to  +80°C,  respective  cleanser  needs  to  be 
added. When  it  comes  to indicators, it is forbidden to apply  water-jet  cleaning 
method,  use  of  hot  water  is  not  allowed.  It  is  recommended  to  cover  the 
indicators for the time of pressure washing of the surroundings. 

 

 

 

While  cleaning  platforms  and  indicators  of  waterproof  platform  scales  do  not 
use  either  intense  water  jet  or  hot  water,  this  is  to  avoid  damage  of  silicone 
bellow  of  platform  sensor  cover  and  indicator's  operation  panel  or  glands. 
Platforms  of  platform  scales  can  be  water-jet  cleaned  when  uninstalled,  they 
can also be cleaned by immersion into water. 

 

 

 

Содержание HX7

Страница 1: ......

Страница 2: ...2 JULY 2020...

Страница 3: ...ately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery discharge in case of prolonged storage of the de...

Страница 4: ...unctional Scales 15 7 1 2 Platform Scales HX7 4 xx C HX7 4 xx H HX7 4 xx H Z Series 16 7 1 3 Ramp Scales HX7 4N Series 16 7 1 4 Track Scales HX7 2K Series 17 7 2 Levelling 1 Load Cell Platform Scales...

Страница 5: ...ed to repair or exchange all elements that appear to be faulty by production or by construction B Defining defects of unclear origin and means of their elimination can only be realized with the assist...

Страница 6: ...tton You can use a solution of water and detergent soap dishwashing detergent glass cleaner Gently rub the cleaned surface and let it dry Repeat the cleaning process if needed In the case of hard to r...

Страница 7: ...cators of all scales feature stainless steel housings polyester overlay and polyamide glands Platforms of both livestock and ramp scales their load bearing structures and weighing tracks can be water...

Страница 8: ...ce directly In case of any problems with correct operation of the scale contact the closest manufacturer s service point In case of defects deliver the faulty product to the manufacturer s service poi...

Страница 9: ...oated steel 1 load cell scale design the main components 1 load cell scale design the main components 1 weighing pan 2 cross 3 load cell 4 base 6 2 Multiple Load Cell Scales Multiple load cell HX7 sca...

Страница 10: ...7 scale with load cell modules is intended to carry out mass measurement of silos Modules are built into construction of ground fixed silo s support In most cases the scale design includes 3 4 load ce...

Страница 11: ...tor option 4 RS232 M12 8P connector 5 RS232 M12 8P connector option 6 RS232 M12 8P connector option 7 RS485 M12 8P connector option 8 Cable gland for a cable of a weighing platform 1 9 Cable gland for...

Страница 12: ...in5 GND Pin6 GND Pin7 24VDC Pin8 24VDC 4INPUTS Pin1 OUT1 Pin2 OUT2 Pin3 WY3 Pin4 OUT4 Pin5 COM Pin6 24VDC Pin7 GND Pin8 NC 4OUTPUTS Pin1 IN1 Pin2 IN2 Pin3 IN3 Pin4 IN4 Pin5 COM Pin6 24VDC Pin7 GND Pin...

Страница 13: ...inputs and 12 outputs It is equipped with optoisolated inputs and semiconductor outputs and enables free configuration of both the inputs and outputs using indicator menu For 12IN 12OUT module the ind...

Страница 14: ...6 7 2 I O Schematic Diagrams 4 inputs 4 outputs 6 8 Operation Panel Keys Press to switch the device on off Press to enter the main menu Press to log in Press to cancel the message Press to zero the sc...

Страница 15: ...Programmable key assigned to an on screen button Programmable key assigned to an on screen button Programmable key assigned to an on screen button Programmable key assigned to an on screen button 7 S...

Страница 16: ...installed 7 1 3 Ramp Scales HX7 4N Series Take the device out of the packaging pallet Prior to installation mount a steel bracket 2 onto a foot base 1 do it using an expanding ring 3 next screw the f...

Страница 17: ...on must be paid to stresses and the weighing system i e the weighing system must lack the stresses 7 2 Levelling 1 Load Cell Platform Scales It is necessary to level the scale do it by turning its fee...

Страница 18: ...splayed continuously battery charged within 75 100 range of permissible voltage pictogram displayed continuously battery charged within 50 75 range of permissible voltage pictogram displayed continuou...

Страница 19: ...re the home screen is to be found in PUE HX7 indicator software manual 8 1 Top Bar The top bar displays the following information Working mode name and symbol Device name Wireless communication on Com...

Страница 20: ...n customize the screen 8 4 Pictograms The pictograms assigned to operation panel keys are to be found underneath the workspace You can define on screen pictograms individually for each working mode 9...

Страница 21: ...when editing numeric and text values Press to select change working mode Press to confirm accept modifications Press to go back or to discard entering parameter modifications Press to go up the menu o...

Страница 22: ...ntout template universal variable value etc Button functions change depending on the edit box type 9 3 1 Numerical Box Where Digit mode To change keyboard working mode press key Keyboard working mode...

Страница 23: ...it 6 Press to enter digit 7 Press to enter digit 8 Press to enter digit 9 Press to enter digit 0 Press to enter dot hold the key for a few seconds Press to delete one character Press to exit the edit...

Страница 24: ...Press to enter Press to enter a b c Press to move the cursor to the left long press Press to enter d e f Press to move the cursor up long press Press to enter g h i Press to move the cursor to the rig...

Страница 25: ...tic for a particular interface language are automatically added to the table when the given language gets selected Diacritical sign table Polish Diacritical sign table English German French Spanish Wh...

Страница 26: ...e weighing pan Read the result when stability marker is displayed 10 1 Operation conditions for 1 load cell scales To assure long term operation and correct mass measurements follow the rules presente...

Страница 27: ...ced on the scale must remain unsupported ramp scales trucks used in meat plants it is necessary to select platform matching the span of truck casters this is to make sure that in case of trucks of wei...

Страница 28: ...28 11 DIAGRAMS OF CONNECTION CABLES Indicator computer cable Indicator printer cable EPSON...

Страница 29: ...29 Indicator printer cable ZEBRA Indicator IN OUT cable Indicator barcode scanner cable LS2208...

Страница 30: ...P cable Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends 12 TECHNICAL SPECIFICATION For technical specifications of respective scales go to RADWAG website...

Страница 31: ...31...

Отзывы: