12
M16MI325 A03_06/18
USER SETTINGS
ACCESS
You access to User settings in 3 steps:
From Auto, Comfort, Eco or Frost protection mode :
Information display
1
Information display
1
User
= user settings
Press for 5
seconds
1
Press briefly
twice
2
Press briefly
3
Setting sequence:
Backlighting
Frost protection temperature
Maximal Boost duration
Maximum ambient temperature
BACKLIGHT SETTING
2-
Press
to save and move to the next setting.
SETTING THE FROST PROTECTION
TEMPERATURE
Your device is preset at 7°C. You can adjust the Frost protection
temperature from 5°C to 11°C, by intevals of 0.5°C.
4-
Press
to save and move to the next setting.
To exit the user settings, press
twice.
3-
Press
or
to obtain the temperature you require.
1-
Three modes can be set:
Version without occupancy detector:
L1
= Temporary backlighting: Backlight of the display when a but-
ton is pressed.
L2
= Non-stop backlighting: Backlight of the display all the time.
L3
= In this version, the device will work according to the L1 mode.
Version with occupancy detector:
L1
= Temporary backlighting: Backlight of the display when a but-
ton is pressed or during occupancy detection.
L2
= Non-stop backlighting: Backlight of the display all the time.
L3
= Temporary backlighting: Backlight of the display when a but-
ton is pressed.
L3 mode is the default setting.
Press
or
to choose the setting you require.
To exit the user settings, press
twice.
SETTING OF THE MAXIMUM DURATION
OF AUTHORISED BOOST
The maximum duration of Boost is preset at 60 minutes. You can adjust
it from 30 to 90 minutes by intervals of 30 minutes.
7
- The Boost symbol and the heating indicator appear on the display
and the preset duration of 60 minutes flash.
8
- Press
or
to display the desired duration.
EN