Radlink 2200 Скачать руководство пользователя страница 15

00.09-013 Rev. E – Radlink GPS Tablet User Manual (07/31/2017)  

Page 15 of 16 

WARNINGS FOR RADLINK GPS TABLET UNIT 

 

 
Radlink Technical Support is the only approved Service 
Personnel  
 
Recommended that the user reads Radlink GPS user 
manual prior to operating unit 
 
Do not touch the Radlink GPS Tablet and the patient at the 
same time 
 
The Radlink GPS Tablet has no “Applied Parts”, or parts 
meant for direct patient contact 
 
 WARNING - No modification of the Radlink GPS Tablet is 
allowed 
 
WARNING - Do not modify the Radlink GPS Tablet without 
authorization of the manufacturer 
 
WARNING - If the equipment is modified, appropriate 
inspection and testing must be conducted to ensure 
continued safe use of the equipment 
 
Other equipment or network/data couplings shall not be 
attached to any signal input/output port except for those 
which form the GPS Tablet unit  
 
Contraindications:  Do not use the Radlink GPS Tablet for 
mammography 
 
No parts of the Radlink GPS Tablet shall be serviced or 
maintained while in use with a patient 
 
No parts of the Radlink GPS Tablet are suitable for use 
within the patient environment 
 
 Do not use near water/liquid - unit does not have Ingress 
Protection Rating for liquid 
 
To maintain wireless signal strength, do not use near 
source of EMC or RF interference 
 
The GPS Tablet (13-14-001) full list of notices and warnings 
can be found at 

www.surface.com/support

 for the 

Microsoft Surface Book 
 
The Wireless Display Adapter (13-14-002) full list of 
notices and warnings can be found at 

www.surface.com/support

 for the Microsoft Wireless 

Display Adapter 
 

Tablet Wireless LAN Adapter (13-14-004) full list of notices 
and warnings can be found at 

www.asus.com/support/

 for 

the ASUS USB-AC51 
 
WARNING - There is potential for electromagnetic or other 
reciprocal interference between the Radlink GPS Tablet 
and other medical electrical devices together.  To minimize 
the possibility of such interference, keep other medical 
electrical equipment away from the Radlink GPS Tablet 
unit 
 
Installation is not required for the Radlink GPS Tablet 
 
The Radlink GPS Tablet does not create any “waste 
products” during standard use.  The device owner should 
properly dispose of the GPS Tablet hardware in 
accordance with government regulations at the end of the 
device life 
 
Position the Radlink GPS Tablet so the mains plug is readily 
accessible for quick disconnection from the power supply 
 
The Radlink GPS Tablet uses batteries.  The device owner 
should properly dispose of the GPS Tablet’s batteries in 
accordance with government regulations at the end of the 
device life. 
 
WARNING - The Radlink GPS Tablet is not configurable (or 
reconfigurable) 
 
An additional multiple socket-outlet or extension cord 
shall not be connected to the Radlink GPS Tablet while 
plugged in and charging 
 
Only connect items that have been specified as part of the 
Radlink GPS Tablet or have been specified as being 
compatible with the unit. 
 
To disconnect the Radlink GPS Tablet from power, remove 
the quick-connect power cable on the right side of the 
keyboard.  
 
The accessories of the Radlink GPS Tablet and 
modifications during the actual service life require 
evaluation to the requirements of IEC 60601-1. 
 
WARNING – To prevent falling hazards and potential 
damage, hold the Radlink GPS Tablet firmly or place 
securely on tabletops and desks 

 

 

Содержание 2200

Страница 1: ...00 09 013 Rev E Radlink GPS Tablet User Manual 07 31 2017 Page 1 of 16 Radlink GPS Tablet User Manual Galileo Positioning System ...

Страница 2: ...es captured during the procedure For posterior approach THA procedures a flat panel detector DR panel is used to capture intraoperative images which takes approximately four seconds to appear on the GPS Tablet For anterior approach THA procedures C Arm images are instantaneously transferred to the GPS Tablet using the Radlink Wireless C Arm Kit Table of Contents GPS Tablet System Overview 3 Radlin...

Страница 3: ...31 2017 Page 3 of 16 GPS TABLET SYSTEM OVERVIEW Wireless C Arm Kit Images sent via Wireless to GPS Tablet Images sent via Wireless to GPS Tablet DR Panel Bucky Cart Flat Panel Detector Images sent via Wireless to Hospital PACS Hospital PACS EMR System ...

Страница 4: ...essing Image Manipulation Overlay Templating Overlay Line Angle Measurements Regulatory Certifications Radlink FDA 510 k K142718 External Standards IEC 60601 1 Medical Electrical Equipment Safety IEC 60601 1 2 Medical Electrical Equipment EMC IEC 60601 1 6 Usability for Medical Devices Radio Frequency Compliance U S A FCC Part 15 Subpart B Subpart C Expected Device Lifetime GPS 5 7 Years Without F...

Страница 5: ...Radlink GPS allows imaging of the pelvis knee skull chest shoulder spine abdomen and extremities The digital images are transmitted from the panel or from a connection to PACS via computer networks or from a video input port to a personal computer PC where they may be displayed processed altered overlaid with templates compressed for archiving or transmission via computer networks to other medical...

Страница 6: ...le clicking the desktop icon Radlink Pre Op or open the Radlink Pro Imaging Acquisition Software by double clicking the desktop icon Radlink Pro Imaging SYSTEM SHUT DOWN 1 Shut down the GPS Tablet using standard Windows shut down procedure a Click the Windows icon Start Button in the bottom left corner of the desktop b Click Power c Click Shut Down 2 Once the GPS Tablet has shut down via Windows c...

Страница 7: ... where the XXXX represents the last 4 digits of the Wireless C Arm Kit s serial number 4 The password for the network will be radlinkwca 5 Confirm the network shows No Internet Secured under the wireless network name 6 Open the Radlink Pro Imaging software and ensure the system mode is properly set by clicking Manage in the upper right and then selecting Wireless Frame Grabber for the System Mode ...

Страница 8: ...ngs in the bottom right corner USING THE RADLINK GPS TABLET IN AN ANTERIOR APPROACH THA PROCEDURE 1 Make sure that your Radlink Wireless C Arm Kit is on and connected to the wireless internet network RadlinkWCAXXXX where XXXX is the last 4 digits of the Wireless C Arm Kit serial number 2 If images need to be pulled from PACS and WiFi access is not available use the USB Ethernet LAN adapter with an...

Страница 9: ...tion the X ray generator between the GPS and the DR Panel Lead inside the mobile X ray generator can interfere with the wireless communication resulting in a lost connection or the inability of the panel to acquire images 1 Turn on the DR Panel To turn on the DR panel press and hold the power button until the panel turns on Once the DR panel has been turned on follow Steps 2 12 to complete the THA...

Страница 10: ...ftware goes to QC Image not Scan In this case just click the Scan button on the top bar to proceed to the acquisition page 7 Click Start DR 8 Take the intraoperative X ray The image will appear in the viewing window 9 Use Image Orientation buttons to rotate the image 10 Use the Image Appearance buttons to Window Level Zoom in etc 11 Refer to the Surgeon s Checklist user manual to take measurements...

Страница 11: ...y 1 With the label at the bottom facing front and downward insert the battery into the charger 2 When the battery is fully charged the four solid green lights will be illuminated If the battery is not fully charged the lights will blink To insert the battery into the DR panel 1 Place the battery in the slot on the DR panel The label on the battery should be on the opposite side of the label of the...

Страница 12: ...r but don t apply liquids directly to your GPS Tablet Don t use window cleaner or other chemical cleaners on your GPS Tablet Keep it covered Close the cover while you re in transit or not using your GPS Tablet Keep it out of the sun Don t leave your GPS Tablet in direct sunlight for a long time Ultraviolet light and excessive heat can damage the display 3 Power cords like any other metal wire or c...

Страница 13: ... it to reconfigure itself Automatic Windows Updates Wait for the automatic updates to complete if the system is too slow Computer may be out of disk space storing too many images Call Radlink Technical Support DR Status light reads Initializing instead of Ready or DR Panel Flat Panel Detector will not connect The wireless communication between the panel and the GPS Tablet is blocked by a lead shie...

Страница 14: ...otified Body 0123 Notified Body TÜV SÜD Product Service GmbH Ridlerstr 65 80339 Munich Germany Radlink European Union Representative Name and Address of Manufacturer Date of Manufacture Serial Number Refer to instruction manual Input voltage is alternating current AC Earth ground Temperature limit to which this equipment can be safely exposed Indicates the range of humidity to which this equipment...

Страница 15: ...lay Adapter Tablet Wireless LAN Adapter 13 14 004 full list of notices and warnings can be found at www asus com support for the ASUS USB AC51 WARNING There is potential for electromagnetic or other reciprocal interference between the Radlink GPS Tablet and other medical electrical devices together To minimize the possibility of such interference keep other medical electrical equipment away from t...

Страница 16: ...00 09 013 Rev E Radlink GPS Tablet User Manual 07 31 2017 Page 16 of 16 Radlink Inc www radlink com 310 643 6900 815 N Nash St El Segundo CA 90245 ...