![RADLEY 1281-914 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/radley/1281-914/1281-914_owners-manual_780648016.webp)
15
Rotary Tool Kit - Owner's Manual
MAINTENANCE
GENERAL
WARNING: When servicing, use only identical
replacement parts. Use of any other part may
create a hazard or cause product damage.
DO NOT use solvents when cleaning plastic
parts. Most plastics are susceptible to damage
from various types of commercial solvents and
may be damaged by their use. Use clean cloth to
remove dirt, dust, oil, grease etc.
WARNING: Do not at any time allow brake fluids,
gasoline, petroleum-based products, penetrating
oils, etc. to come in contact with plastic parts.
They contain chemicals that can damage, weaken
or destroy plastic.
DO NOT abuse power tools. Abusive practices
can damage the tool as well as the workpiece.
WARNING: DO NOT attempt to modify this
rotary tool or create accessories not recommended
for use. Any such alteration or modification is
misuse and could result in a hazardous condition
leading to possible serious injury. It will also void
the warranty.
LUBRICATION
All the bearings in this rotary tool are lubricated with a sufficient amount of high- grade
lubricant for the life of the unit under normal conditions. Therefore, no further lubrication
is required.
REPLACING THE CARBON MOTOR BRUSHES
The carbon motor brushes will wear down and require replacing. The time intervals between
replacements will vary depending upon the torques being achieved and the hours of use. It is
recommended that the brushes be checked after each 10 hours of use. When the length of the
carbon brush reaches 1/4" (6.35 mm), the brushes should be replaced.
WARNING: Unplug the tool from the power source.
1. Use a small slot screwdriver and remove one brush cap (1) (Fig. 5). Turn the brush cap
counterclockwise to remove it from the motor housing.
2. Pull the spring & brush assembly (2) from the brush holder (3) in the motor housing (4).
3. Insert the new spring & brush assembly into the motor housing.
4.Compress the spring into the brush holder and thread the brush cap back into the motor
housing.
Fig. 5
NOTE: Make sure the brush cap
threads are not cross threaded. Do NOT
over tighten.
Repeat steps #1 to #4 and replace the
second carbon brush located on the
opposite side of the motor housing.