NOTES:
1. When the charger is plugged into the wall receptacle and NO battery is on the
charger, the green indicator light (5) will turn ON indicating the charger is “live”.
2. When a discharged battery is installed on the charger, the green indicator light will
turn OFF and the red indicator light (6) will turn ON. The red indicator light indicates
the battery is being charged.
3. If the red indicator light does not come ON, check to make sure battery pack is slid
fully onto the charger and the electrical outlet is working properly.
4. See Fig. 2 below for other indicator light functions.
5. A discharged battery pack should be fully charged in 60 minutes.
6. It is normal for the battery charger to hum and be warm to the touch during operation.
7. If the battery pack does not charge properly, check to make sure the electrical outlet
is “live”.
8. Do NOT charge batteries when the work area or the battery temperature is at or below
41°F/5°C or above 105°F / 40.5° C.
GREEN
LIGHT
RED
LIGHT
BATTERY
INSERTED
INTO
CHARGER
CHARGING STATUS
ON
OFF
NO
Charger connected
to power supply
OFF
ON
YES
Battery being charged
ON
OFF
YES
Battery fully charged
OFF
ON
YES
Battery is charged
but not operational
on tool. This may
indicate defective /
bad contact on battery
or charging conditions
are either too hot or
too cold.