Verify switch operation
7
Verify switch operation
Use these steps to view port status and to enable ports on the Base Ethernet and the Fabric Ethernet
switches.
View port status
1. Verify you are at this prompt.
ATCA-2210#
If you are not at the appropriate prompt, see
Connect to the SCM
on page 6
for instructions on
how to get there.
2. Enter the applicable command for the switch you are verifying.
3. Enter this command to show the status of the ports.
show port all
View the status information of the ports to see which ports are enabled. If needed, press the space
bar to view more of the list.
4. Proceed to the applicable section or step:
To enable all ports, see
Enable all ports
on page 8
.
To enable only specific ports, see
Enable specific ports
on page 8
.
To leave all ports disabled, continue with
step 5
.
5. Enter the
exit
command to return to the
ATCA-2210#
prompt.
If you are asked to save changes, enter
y
for
yes
or
n
for
no
. If you choose
y
for
yes
, this
configuration is saved as the startup configuration.
6. Enter the
exit
command to log off the SCM.
7. If you have two SCMs installed, repeat the above steps on the other SCM.
Switch
Command to enter
Resulting prompt
Base Ethernet
base-ethernet
ATCA-2210-Base#
Fabric Ethernet
fabric-ethernet
ATCA-2210-Fabric#