Installation Guide

6

Connect to the SCM

The SCM can be accessed by an external computer through the serial and the Ethernet maintenance 
ports. Use the serial port to perform diagnostic and verification procedures or to enable or disable the 
Shelf Manager. Use the Ethernet maintenance port to connect the SCM to the network and to perform 
configuration procedures.

Note:

 If you have two SCMs installed, connect to each one separately.

Connect to the serial port

1. Connect the included serial port cable by plugging one 

end into the RJ-45 serial port labeled “LMP SER” on the 
SCM. 

2. Connect the cable’s other end to the COM1 or the COM2 

serial port of an external computer, such as a laptop. 

3. Start a terminal-emulator application, such as Procomm 

Plus® or minicom, from the operating system on your 
computer or laptop. Specify 115,200 baud, 8 data bits, 
no parity, one stop bit, and no hardware or software flow 
control. 

4. Press the Enter key and verify you get a 

login

 prompt. 

Enter 

admin

 at the prompt. 

5. Verify that you receive a welcome message and a prompt 

showing 

ATCA-2210#

.

Important:

 If the SCM has been installed in a non-

RadiSys shelf, you may receive a 

DEBUGMODE

 prompt 

rather than the 

ATCA-2210

 prompt. If this occurs, disable the SCM’s on-board Shelf Manager. See 

Disable the Shelf Manager on the SCM

 on page 10

 for more information. 

Connect to the Ethernet maintenance port

1. Connect a crossover Ethernet cable between the SCM’s Ethernet maintenance port, which is 

labeled “LMP ETH,” and a Linux host computer that is connected to your network.

2. Configure the computer to a subnet IP address (10.0.0.x) and set the netmask to 255.255.255.0.

3. On the computer, verify Telnet access to IP address 10.0.0.1 (port 23).

4. At the 

login

 prompt, enter 

admin

 and verify you receive the 

ATCA-2210#

 prompt. To log off the 

SCM at any time, enter

 

the

 exit 

command. 

Note:

 To connect to the Linux shell on the SCM, use either a serial port or Telnet connection. After 

connecting, log in as 

root

 and enter 

ifconfig

 to view eth0 configuration settings.

ATCA - 2210

COM-E

USB

COM-E

SER

COM-E

ETH

XFP

 1/1

LMP

ETH

LMP

SER

OOS

P

W

R

ACT

P

O

R

T

LINK

LINK

Serial port

(LMP SER)

Ethernet 
maintenance 
port

(LMP ETH)

Содержание PROMENTUM ATCA-2210

Страница 1: ...14 or ATCA 6016 shelf A 9 pin D shell to RJ 45 serial port cable shipped with the SCM A standard crossover Ethernet cable Adequate ventilation for the shelf Install SFPs or XFPs on the SCM The SCM comes with sockets for small form factor pluggable SFP and 10 Gigabit small form factor pluggable XFP transceiver modules If SFPs and XFPs are installed they can provide external connections to the Ether...

Страница 2: ...e adequately grounded 2 Remove the transceivers and the SCM from their antistatic bags 3 On the SCM s faceplate remove the filler plugs from the sockets in which you are installing the SFP or the XFP transceivers For sockets not being used keep the filler plugs in place to protect the internal components of the board 4 Make sure the transceiver s bale the latch on the cable side of the transceiver...

Страница 3: ...side is on the left and the flat smooth side is on the right If the SCM is oriented horizontally insert the filler plug so the recessed side is on the bottom and the flat smooth side is on the top SFP filler plug installation If the SCM is oriented vertically insert the filler plug so the connector side and retaining clip are on the left If the SCM is oriented horizontally insert the filler plug s...

Страница 4: ...stallation of the SCM in the non RadiSys shelf you must disable the SCM s on board Shelf Manager 1 Install the SCM in the shelf on page 5 2 Disable the Shelf Manager on the SCM on page 10 3 Verify switch operation on page 7 ____ ____ ____ Removed from a non RadiSys shelf and reinstalled in a RadiSys shelf Pre removal configuration required Before you remove the SCM from the non RadiSys shelf you m...

Страница 5: ...the SCM If the SCM does not slide easily make sure you are inserting the SCM into the correct slot and that it is aligned properly 5 Once the SCM is inserted all the way into the shelf simultaneously close both ejector latches inward This seats the SCM s connectors into the shelf s backplane The hot swap H S LED light flashes until the SCM is fully powered Once powered the LED light turns off If t...

Страница 6: ... the prompt 5 Verify that you receive a welcome message and a prompt showing ATCA 2210 Important If the SCM has been installed in a non RadiSys shelf you may receive a DEBUGMODE prompt rather than the ATCA 2210 prompt If this occurs disable the SCM s on board Shelf Manager See Disable the Shelf Manager on the SCM on page 10 for more information Connect to the Ethernet maintenance port 1 Connect a ...

Страница 7: ...e enabled If needed press the space bar to view more of the list 4 Proceed to the applicable section or step To enable all ports see Enable all ports on page 8 To enable only specific ports see Enable specific ports on page 8 To leave all ports disabled continue with step 5 5 Enter the exit command to return to the ATCA 2210 prompt If you are asked to save changes enter y for yes or n for no If yo...

Страница 8: ...up configuration Note If the SCM includes the optional Procelerant CE3100 COM Express module you may need to perform some additional port configuration procedures See the ATCA 2210 Switch and Control Module Reference for more information 3 Enter the exit command to return to the ATCA 2210 prompt 4 Enter the exit command to log off the SCM 5 If you have two SCMs installed repeat these steps on the ...

Страница 9: ...s configuration is saved as the startup configuration Base Ethernet switch interfaces ATCA 6000 backplane slots s 0 p 1 6 9 14 ATCA 6006 backplane slots s 0 p 3 6 ATCA 6014 backplane slots s 0 p 1 6 9 14 ATCA 6016 backplane slots s 0 p 1 7 10 16 Front panel optical s 1 p 5 9 Internal ports s 2 p 1 3 4 RTM s 3 p 5 8 or p 5 6 depends on SCM configuration Base Ethernet switch internal ports 2 1 The l...

Страница 10: ...s command to exit the platform management CLI exit 5 If you have two SCMs installed repeat these steps on the other SCM Disable the Shelf Manager on the SCM By default the SCM is configured to function in a RadiSys shelf For an SCM to operate in a non RadiSys shelf you must disable the Shelf Manager on the SCM 1 Connect the included serial port cable by plugging one end into the RJ 45 serial port ...

Страница 11: ... Enter ShMC Mode Enable 0 Disable 1 Enter 1 to disable the on board Shelf Manager The menu prompt displays upon completion of the process 13 To verify the on board Shelf Manager is disabled enter 41 14 The following text displays Get SCM ShMgr Mode Enter address in hex Enter the same host address you entered for step 11 If the on board Shelf Manager is disabled this message displays SCM ShMgr Mode...

Страница 12: ...e Enter key and verify you get a login prompt Enter root at the prompt 5 To determine the version of SCM s on board Shelf Manager enter the following at the ATCA 2210 prompt resys_debug h 6 After determining the version number enter the appropriate command 7 Once the software tool has completed its initialization the host address is displayed Make a note of this address for an upcoming step Typica...

Страница 13: ...hip with a factory installed basic software package Once the SCM is installed and depending on your organization s needs you may choose to change the BIOS setting or install an operating system and drivers See the ATCA 2210 Switch and Control Module Reference for instructions on performing such procedures Where to go from here See the ATCA 2210 Switch and Control Module Reference for detailed info...

Страница 14: ...sit the RadiSys Web site at www radisys com for product information and other resources Downloads manuals release notes software etc are available via the Technical Support Library product links at www radisys com support or the product pages at www radisys com products ...

Отзывы: