Flash once every 0.4 second 

System output self-check failed 

 

Note

: In the above table, the mixed prompt mode of the power light and the status light means that the two 

prompts of system states  are executed simultaneously. The  prompts of power  light and the status light  are 

independent, which means the two prompts of system states can be executed independently. 

 
 

5.3 Mixed prompt of motor and light 

In the mixed prompt mode of the motor sound and indicator light, the red light works, but the green light doesn't. 

At the same time, when there is a battery over-voltage warning or battery under-voltage warning, the system 

state prompt will remove the motor sound prompt, and only retain the indicator light prompt. In the two system 

states  of  system  high  temperature  warning  and  system  low  temperature  warning,  the  time  interval  of  two 

consecutive motor sounds is 1.5 seconds, while in the two system states of throttle signal loss and abnormal 

throttle signal, the time interval of two consecutive motor sounds is 2.5 seconds. 

 

In this ESC system, the system states corresponding to the mixed prompt of the motor sound and indicator 

light are as follows: 

 

Motor sound and red indicator light 

System state 

Four consecutive short beeps 

System high temperature warning 

(Above 85

Flash once every 0.2 second 

Three consecutive short beeps 

System low temperature warning 

(Below -40

Flash once every 0.4 second 

One short beep 

Throttle signal loss 

Flash once every 0.6 second 

Two consecutive short beeps 

Abnormal throttle signal 

Flash once every 0.8 second 

 

Meanwhile, when in the normal operating state mentioned above, the motor will respond to the signal. But in 

other  abnormal  operating  state  mentioned  above,  ESC  will  terminate  the  operation  of  the  motor,  with  no 

response  to  signal  input.  At  this  time,  the  system  can  only  enter  the  normal  operating  state  after  the 

corresponding fault is eliminated. 

 

Thanks 

Thank you very much for using RadioLink COOL 9030 brushed electron speed regulator. Misuse may cause 

personal injury and equipment damage. Please read the instructions carefully before use and strictly abide by 

the  prescribed  operating  procedures.  We  do  not  assume  any  responsibilities  arising  from  the  use  of  this 

product, including but not limited to compensation for incidental or indirect losses. At the same time, we do not 

assume  any  responsibilities  arising  from  unauthorized  modifications  to  the  product.  We  have  the  right  to 

change product design, appearance, performance, and usage requirements without notice. 

Содержание COOL 9030

Страница 1: ...ehicles Drift Cars Crawlers Trailers Bait Boats Rescue Boats Surveying Boats Note This manual only introduces the basic usage of RadioLink COOL 9030 brushed ESC For more information such as tutorials and FAQ please access to RadioLink website www radiolink com or send mail to after_service radiolink com cn ...

Страница 2: ... 3 1 1 COOL 9030 Overview 3 1 2 Specifications 4 Part 2 Connection of COOL 9030 5 2 1 Power Input 5 2 2 Motor output 6 2 3 Signal input 7 Part 3 Throttle calibration 8 Part 4 Usage of Jumper Cap 9 Part 5 ESC status 10 5 1 Motor sound 11 5 2 Indicator light 11 5 3 Mixed prompt of motor and light 12 Thanks 12 ...

Страница 3: ...nected for a long time without use the battery will eventually be completely discharged which will cause the malfunction of the battery or ESC RadioLink is not responsible for any damage caused by incorrect operation Part 1 Introduction of COOL 9030 1 1 COOL 9030 Overview Power input The power input of the ESC is connected to the power supply At the same time the voltage range of connected power s...

Страница 4: ... input power supply and the output voltage of BEC Details will be introduced later LED light description Power light The power light is used to indicate the current self check and power supply status of the ESC system The color of the light is green Details will be introduced later Status light The status light is used to indicate the current self check and operating status of the ESC system The c...

Страница 5: ...There is no positive or negative connection between the brushed motor and the ESC If the motor turns incorrectly you can directly change the direction of the motor through the servo phase in the menu of the transmitter or exchange the connection of the two motor output cables of ESC Make sure the right connection and good contact between the motor and the ESC Connection to the battery The battery ...

Страница 6: ...rotection state and the battery voltage rises back to the half power protection value the system will exit the under voltage protection state Then the system will return to normal operation and the normal output control of the motor is restored Half power protection It is half power output protection state When the voltage of the input power supply is lower than the value the ESC will reduce the o...

Страница 7: ...oncrete cases to prevent the ESC and motor from being damaged or even battery damage accidents 2 3 Signal input The signal input the throttle signal input of this brushed DC ESC can only identify the PWM signal output by a single channel of the receiver The signal with multiple channel codes such as PPM signals S BUS signals etc cannot be recognized At the same time the characteristics of the PWM ...

Страница 8: ...ote controller such as servo output ratio and servo midpoint value etc Calibrate the throttle at this time so that the ESC can be adjusted to the signal output of the receiver to achieve the expected effects COOL 9030 is a two way ESC so the throttle calibration method is the same as that of the common two way ESC The specific steps are as follows ESC Calibration Method Preparation Connect the ESC...

Страница 9: ... output voltage Jumper cap 1 and 2 are used to set the operation mode of the ESC Jumper cap 3 is for battery type and jumper cap 4 for BEC output voltage The different states of the 4 sets of jumper caps will correspond to the different operation modes of the ESC Choose the operation mode you need determine the type of the battery you use and the requirements for the BEC Then refer to the followin...

Страница 10: ...Type When using different types of batteries change the state of Jumper cap 3 to make the battery type match the actual battery Insert Jumper cap 3 when using a lithium battery and remove Jumper cap 3 when using a non lithium battery Wrong state of Jumper cap 3 may cause serious over discharge of the battery and damage the battery Be sure to check Jumper cap 3 to confirm the battery type of the ES...

Страница 11: ...check battery type report and operation allowed in sequence as shown in the table below If the sound of the motor is incomplete when the ESC starts inspect the ESC and the equipment connected Motor Sound ESC status Tone beep Do Re Mi Self check finished Short beep Battery type report Long beep Operation allowed Note There are three consecutive tones Do Re Mi in tone beep state of the motor The num...

Страница 12: ...ht are as follows Motor sound and red indicator light System state Four consecutive short beeps System high temperature warning Above 85 Flash once every 0 2 second Three consecutive short beeps System low temperature warning Below 40 Flash once every 0 4 second One short beep Throttle signal loss Flash once every 0 6 second Two consecutive short beeps Abnormal throttle signal Flash once every 0 8...

Отзывы: