background image

2

3

Preface

About this guide

CAUTION: This guide provides basic operating instructions for the RD5100H

2

O locator 

and transmitter. It also contains important safety information and guidelines and as 
such should be read in its entirety before attempting to operate the RD5100H

2

O locator 

and transmitter.

This guide is intended as a quick reference guide only. For detailed instructions, including 
the use of accessories, please refer to the RD5100H

2

O locator operation manual, which is 

available for download from: 

www.radiodetection.com

Certificates of conformity for the RD5100H

2

O locator and transmitter can be 

found at: 

www.radiodetection.com

 WARNING: Direct connection to live conductors is POTENTIALLY LETHAL.  

Direct connections to live conductors should be attempted by fully qualified personnel 
only using the relevant products that allow connections to energized lines.

 WARNING: The transmitter is capable of outputting potentially lethal voltages. 

Take care when applying signals to any pipe or cable and be sure to notify other 
technicians who may be working on the line.

 WARNING: Risk of Hearing Loss. The locator emits noise levels which can 

cause partial or total hearing loss. When using headphones these must have an 
independent volume control. Set the volume level to its lowest value before donning 
the headphones.

 WARNING: This equipment is NOT approved for use in areas where hazardous 

gases may be present.

 WARNING: When using the transmitter, switch off the unit and disconnect cables 

before removing the batteries.

 WARNING: The RD5100H

2

O locator will detect most buried conductors but there 

are some objects that do not radiate any detectable signal. The RD5100H

2

O, or any 

other electromagnetic locator, cannot detect these objects so proceed with caution. 
There are also some live cables which the RD5100H

2

O will not be able to detect in 

Power mode. The RD5100H

2

O does not indicate whether a signal is from a single cable 

or from several in close proximity.

 CAUTION: Batteries can get hot after prolonged use at full output power.  

Take care while replacing or handling batteries.

eCert

The RD5100H

2

O locator is safety equipment which should be regularly  

checked to ensure its correct operation.
eCert

1

 provides a thorough test of the RD5100H

2

O’s locating circuitry, and 

supplies a Radiodetection Calibration Certificate when a positive test result  

is obtained.
Refer to the RD5100 Manager

1

 operation manual for further details. Additional 

purchase may be required.

1 Contact Radiodetection for eCert and RD5100 Manager availability.

3 Year Extended Warranty

The RD5100H

2

O locator and transmitter are covered by a 1 year warranty as 

standard. Customers can extend their warranty period to a total of 3 years by 

registering their products within 3 months of purchase.
Visit 

https://portal.radiodetection.com/

 to create your company portal 

account, and use the Product page to register your locator or transmitter.
Information on how to create a company account can be obtained from: 

https://support.radiodetection.com

From time to time Radiodetection may release new software to improve the 

performance or add new functionality to its products. By registering, users  

will benefit from email alerts advising about new software and special offers 

related to its product range.
Users can opt-out at any time from receiving software and technical 

notifications, or just from receiving marketing material by contacting 

Radiodetection.

Содержание RD5100 H2O

Страница 1: ...RD5100 H2O Multifunction precision cable and pipe locator User Guide PART NO 90 UG112INT 01 ...

Страница 2: ...bjects that do not radiate any detectable signal The RD5100H2 O or any other electromagnetic locator cannot detect these objects so proceed with caution There are also some live cables which the RD5100H2 O will not be able to detect in Power mode The RD5100H2 O does not indicate whether a signal is from a single cable or from several in close proximity CAUTION Batteries can get hot after prolonged...

Страница 3: ... Down arrow key 11 Backlight sensor 12 Frequency mode key Locator screen icons 13 Target position indicator Indicates position of locator relative to target line 14 Signal strength Numerical indication of signal strength 15 Proportional Left Right arrows Indicates the location of the target relative to the locator 16 Signal strength Bargraph with peak marker 17 Depth Indication of depth reading 18...

Страница 4: ...luminates the user should either recharge the battery pack using the Radiodetection supplied charger or alternatively fit 4 alkaline batteries If alkaline batteries are fitted to the transmitter these will be detected automatically and the transmitter will take its power from the alkaline batteries When the alkaline batteries are low the alkaline low battery level LED will illuminate SYMBOL DESCRI...

Страница 5: ...sition and decreases in 1dB increments in Power mode Rapidly decrease gain steps in 1dB increments in Power Mode Tip Gain values set in Power Mode are stored internally and available when the unit is powered on Locator keys Batteries Internal Battery The RD5100H2 OTx has an internal Li Ion rechargeable battery and is supplied with bespoke charging equipment Use of alternative charging equipment is...

Страница 6: ...n diameter to transfer the transmitter signal to the utility This method of applying the transmitter signal is particularly useful on insulated live wires and removes the need to disconnect the supply to the cable WARNING Do not clamp around uninsulated live conductors WARNING Before applying or removing the clamp around a power cable ensure that the clamp is connected to the transmitter at all ti...

Страница 7: ... means of applying a locate signal to an insulated live wire This is particularly useful with live insulated cables as it removes the need to disable the power and break the line WARNING Do not clamp around uninsulated live conductors WARNING Before applying or removing the clamp around a power cable ensure that the clamp is connected to the transmitter at all times Sondes Flexrods and FlexiTrace ...

Страница 8: ...l strength value will increase Use the proportional arrows target position indicator and signal strength value to guide the locator directly over the target line Figure 2 Figure 2 shows the locator in Guidance Mode and directly over the target line In this position the left and right arrow heads will be displayed simultaneously target position indicator in the centre the signal strength value at i...

Страница 9: ...igh pressure jets of water to clean the equipment If using this equipment in foul water systems or other areas where biological hazards may be present use an appropriate disinfectant Software upgrades From time to time Radiodetection may release software upgrades to enhance features and improve performance of the RD5100H2 O locator or transmitter Software upgrades are free of charge and provided t...

Страница 10: ...m Radiodetection Canada 344 Edgeley Boulevard Unit 34 Concord Ontario L4K 4B7 Canada Tel 1 905 660 9995 Toll Free 1 800 665 7953 rd sales ca spx com Radiodetection Ltd UK Western Drive Bristol BS14 0AF UK Tel 44 0 117 976 7776 rd sales uk spx com Radiodetection France 13 Grande Rue 76220 Neuf Marché France Tel 33 0 2 32 89 93 60 rd sales fr spx com Radiodetection Benelux Industriestraat 11 7041 GD...

Отзывы: