Page
22
of
32
©
2019 Radiocrafts AS
RC232 User Manual (ver 2.01)
RC232 USER MANUAL
Parameter
Addr
(hex)
R
C
1
2
x
x
R
C
1
1
x
x
(H
P
)
R
C
2
5
0
0
(H
P
)
R
C
1
7
x
x
(H
P
)
A
rgum
e
nt
ra
nge
Comment
Default/
Factory Setting
UART_BAUD_RATE
0x30
✔
✔
✔
✔
Baud rate.
BE CAREFUL IF CHANGING AS HOST MAY LOOSE
CONTACT WITH MODULE!
Does not take effect until module is re-booted / reset.
RC12xx
Others
0
0x00
Not used
Not used
1
0x01
600
2400
2
0x02
1200
4800
3
0x03
42400
9600
4
0x04
4800
14400
5
0x05
9600
19200
6
0x06
19200
28800
7
0x07
N.A.
38400
8
0x08
N.A.
57600
9
0x09
N.A.
76800
10
0x0A
N.A.
115200
11
0x0B
N.A.
230400
0x05
RC12xx: 0x06
UART_FLOW_
CONTROL
0x35
✔
✔
✔
✔
UART flow control
0
0x00
None
1
0x01
CTS only
3
0x03
CTS/RTS
4
0x04
RXTX (RS485)
0x00
DATA_INTERFACE
0x36
✔
✘
✘
✘
When transparent mode is selected for MAC_MODE
use synchronous interface
0
0x00
UART using RXD and TXD
1
0x01
Synchronous interface (SDA,
SCL) using RXEN and TXEN for
direction control.
LED_CONTROL
0x3A
✘
✔
✔
✔
0x00
-
0x01
Use to enable LED0/LED1 for RX/TX packet indication.
0
0x00
Disabled
1
0x01
RX/TX indicator
0x00
ENCRYPT_FLAG
0x3E
✘
✘
✘
✔
Default setting for encryption, enabled when set
0
0x00
Disabled
1
0x01
Enabled