Page
16
of
32
©
2019 Radiocrafts AS
RC232 User Manual (ver 2.01)
RC232 USER MANUAL
Command
Details
Comments
ASCII
hex
‘V’
0x56
Voltage monitoring
Argument
Options
Returns
(none)
(none)
1 byte
temperature
+ Prompt (>)
The module provides readings of an internal power supply
voltage monitoring sensor (VCC) through the ‘V’ command.
The module returns an 8 bit character (one byte) indicating the
current power supply voltage level followed immediately by a
second character
which is the prompt (‘>’). The command can
be useful for battery power monitoring.
The VCC value increases with increased supply voltage in 30
mV/step. The power supply voltage is given by:
V = VCC(dec)*0.030 [V]
(example: VCC=0x68 equals 3.12 V)
‘X’
0x58
Exit
This command exits configuration mode and sets module back
in idle mode, ready to send/receive data packets.
Argument
Options
Returns
(none)
(none)
(none)
‘Y’
0x59
Memory Read One Byte
Argument
Options
Returns
Address
See Table 4 for overview of
configuration memory
1 byte value
for given
address
+Prompt (>)
‘Z’
0x5A
Sleep
This command is used to exit configuration mode and enter the
low power SLEEP state when SLEEP_MODE = 0x00. CONFIG
pin must be held LOW while issuing this command. To exit
sleep mode, release CONFIG pin.
Argument
Options
Returns
(none)
(none)
(none)