Radio Thermostat CT32 Скачать руководство пользователя страница 13

PG

 13

Step-by-step wiring diagrams

 

 

WIRES

  3 Wire Heat   GAS MILLIVOLT or 24VAC system 

STEP 1 - Connect the R (or RH) wire to the RH terminal.  This connects the 

heat power.

STEP 2 - Connect the W wire to the W terminal.  

This connects the heat.                

STEP 3 -  Connect the C wire to the C terminal.

Your heater is now connected to the CT32.  

Please Go To Page 6  

WIRES

  4 Wire  Heat  

STEP 1 - Connect the R (or RH) wire to the RH terminal. This connects the 

heat power.

STEP 2 - Connect the W wire to the W terminal. This connects the heat.

STEP 3 - Connect the G wire to the G terminal on the thermostat. This 

connects the fan.

STEP 4 -  Connect the C wire to the C terminal. 

Your system is now connected to the CT32.

Please Go To Page 6

C B O W W

2

 Y Y

2

 R

H

 RC G A 

POWE

R

HVAC SYSTEM

THERMOSTAT

W

R

C

HVAC SYSTEM

THERMOSTAT

C B O W W

2

 Y Y

2

 R

H

 RC G A

POWE

R

W

R

G

C

Содержание CT32

Страница 1: ...stat is designed for use with 24 volt AC HVAC and millivolt gas systems The thermostat is powered by 4AA alkaline batteries and or 24 volt AC C wire or a 12 24 AC or DC source Each thermostat relay lo...

Страница 2: ...e are unusual heating conditions such as in direct sunlight near a lamp radio television radiator register fireplace near hot water pipes in a wall or near a stove on the other side of a wall Do not l...

Страница 3: ...carefully before removing any wiring from existing thermostat Wires must be labeled before they are removed THERE IS NO STANDARD COLOR CODE When remov ing wires from their terminals ignore the color o...

Страница 4: ...DC wall transformer A constant power source is required when using a radio module IMPORTANT If you have both RH and RC you need to remove the jumper wire between these 2 terminals Prepare Wires Please...

Страница 5: ...t the end if the install section to determine your connections contact customer support for help G C W Y RH RC G 6 Wire Heat Cool From HVAC RC C Y RH W C W Y R G 5 Wire Heat Cool From HVAC G C Y R W C...

Страница 6: ...slack back into the wall opening Connect Your Wires Connect labeled wires only to a terminal with the same letter label Insert the wire in the terminal well and tighten the screw securely NOTE If you...

Страница 7: ...CT32 for best appearance 3 Attach the CT32 to the wall with the screws provided 4 If you are mounting the CT32 to sheet rock or if you are using the old mounting holes use the plastic anchors provided...

Страница 8: ...a heat pump with electric auxiliary heat Install 4 AA Batteries Install 4 AA alkaline batteries required following the marked polarity in the battery compartments Put the battery in negative end firs...

Страница 9: ...e Always use new alkaline batteries Failing to replace the batteries when necessary could cause the thermostat to lose power or malfunction If the thermostat loses power then the thermostat will not c...

Страница 10: ...this configuration If you have a Normal HVAC system 1 stage HEAT 1 stage COOL select 1 2 stage HEAT 1 stage COOL select 2 1 stage HEAT 2 stage COOL select 3 2 stage HEAT 2 stage COOL select 4 IMPORTAN...

Страница 11: ...F above room temperature allow the system 2 minutes to respond Verify that heat is blowing from the system Return the Target Temperature to a normal setting Return mode to OFF by pressing the mode bu...

Страница 12: ...oltage HVAC systems This thermostat is digital and your desired heat or cool temperatures can easily be set on the large touch screen with the icons In COOL and heat pump operation an automatic 4 minu...

Страница 13: ...the CT32 Please Go To Page 6 WIRES 4 Wire Heat STEP 1 Connect the R or RH wire to the RH terminal This connects the heat power STEP 2 Connect the W wire to the W terminal This connects the heat STEP 3...

Страница 14: ...ool STEP 1 Connect the W wire to the W terminal This connects the heat STEP 2 Connect the Y wire to the Y terminal This connects to the cooling compressor STEP 3 Disconnect the Rc and Rh terminals by...

Страница 15: ...Heat Pump heat cool without Auxiliary Heat STEP 1 Connect O wire to the O terminal or B wire to the B This connects the change over valve If you have both O and B connect only the O wire to the O term...

Страница 16: ...wire reference under Trane for B wire terminal STEP 2 Connect the AUX 1 AUX 2 to the AUX 1 and 2 respectively This connects the auxiliary heat STEP 3 Connect the Y and Y2 wires to the Y terminals This...

Страница 17: ...Y2 Y2 2nd stage COOL control or 2nd stage compression for a heat pump G or F G FAN control C or X C 24VAC power to power thermostat NOTE TRANE uses B for this connection H H External Humidifier DH DH...

Страница 18: ...or W1 W2 1st stage normal HEAT or 1st stage heat pump auxiliary heat X2 Emergency heat do not connect tape off Zoned Hot Water Heat For Solenoid valve or Motor valve connect the wires based on diagram...

Отзывы: