4.6.2
VU Meter “0” Calibration
The console was calibrated at the factory for an output level of +4dBv, into 600 ohms, when the VU meters indicate “0”.
To calibrate the VU meter “0” indication:
1. Perform output level calibration as detailed previously.
2. Adjust the VU meter calibrate trimmers, located on the Output Board for a “0” reading on
each meter.
4.6.3
Peak LED Trip Point Calibration
The console was calibrated at the factory for an output level of +4dBv, into 600 ohms, when the VU meters indicate “0”,
and for a peak LED trip point of +2VU. To perform Peak LED Trip Point Calibration:
1. Perform output level calibration as detailed previously.
2. Perform VU meter “0” calibration as detailed previously.
3. Adjust oscillator to the desired peak LED trip point level (typically 0 to 3dB hotter).
4. Adjust the peak LED trip point trimmers to that the LEDs just illuminate.
Note: Six channel consoles share the same meters for PROGRAM.1 and PROGRAM.2 monitoring. The front panel VU
meter switch selects the signal to be displayed. Adjustment must be made with both switch settings.
4.6.4
External Monitor Input Level
There is a separate adjustment, located on the Output Board for each of the four stereo external inputs.
1. Connect a high impedance voltmeter to the unmuted monitor output.
2. Select a high level input, and reproduce the nominal level from a test tape, record or CD.
3. Turn the mixing channel “on”, select the program mix bus, and adjust the fader for “0” VU.
4. Depress the “program” monitor input switch.
5. Note the reading on the voltmeter.
6. Feed the nominal input level to any external input and select that monitor input switch.
7. Adjust the associated external input level trimmer until the voltmeter gives the same indication
as in step 5.
8. Repeat steps 6 and 7 for all external inputs.
4.6.5
Cue Bus External Input Level
The level adjustment for the external cue buss input is located on the Output Board.
1. Connect a high impedance voltmeter to the external cue speaker
terminals.
2. Select a high level input, and reproduce the nominal level from a test tape, record or CD.
3. Place the mixing channel into “cue”, and adjust the cue level control VR2 for normal listening
level.
4. Note the reading on the voltmeter.
5. Feed the nominal input level into the external cue input.
6. Adjust the external cue input level trimmer until the voltmeter gives the same indication as in
step 4.
Содержание Millenium-D
Страница 36: ...Radio Systems Millenium D Digital Console Page 36 Illustration D 6 Talkback Wiring ...
Страница 38: ...Radio Systems Millenium D Digital Console Page 38 Illustration E 2 Four Source Router Card ...
Страница 46: ...F 1 7 29 2008 MILLENIUM SMT CONTROL BOARD BLANK BOARD 18515 ASSEMBLY 18516 Analog ASSEMBLY 18522 Digital ...
Страница 51: ...F 6 ...
Страница 55: ...F 10 ...
Страница 56: ...F 11 ...
Страница 57: ...F 12 ...
Страница 61: ...F 16 ...
Страница 62: ...F 17 ...
Страница 63: ...F 18 ...
Страница 64: ...F 19 ...
Страница 68: ...F 23 ...
Страница 69: ...F 24 ...
Страница 70: ...F 25 ...
Страница 72: ...F 27 ...
Страница 73: ...F 28 ...
Страница 76: ...F 31 ...
Страница 77: ...F 32 ...
Страница 94: ...Radio Systems Millenium D Digital Console Page 94 ...