background image

 

 

R

ADIO 

B

RIDGE 

RBM101

U

SER 

G

UIDE

 

 

 

C

OPYRIGHT 

©

 

2017,

 

R

ADIO 

B

RIDGE 

I

NC

.

                                             

R

ADIO 

B

RIDGE 

RBM101

U

SER 

G

UIDE

  P

AGE 

11

 OF 

19

 

 

 

3.3.1.10

 

DB 

 RSSI of last packet  

This command returns the RSSI value of the last packet it received. The return value is a two 
digit ASCII-coded hex value.  

 

3.3.1.11

 

BR 

 Baud Rate 

This command will change the baud rate of the main serial UART. The parameter is a single 
ASCII coded hex character according to the following table. 

Table 9 Baud Rate 

Parameter 

Baud Rate 

1,200 

2,400

 

4,800

 

9,600

 

19,200 

38,400 

57,600 

115,200 

230,400 

If the baud rate setting is successful, 

the module will respond with a “CMD OK” at the 

original 

baud rate and then immediately update to the new baud rate. If the setting is unsuccessful, 
an error message will be returned at the original baud rate  and the  baud rate will remain 
unchanged. 

Note the RBM101 is based on a Silicon Labs Flex Gecko radio. This device 
uses an automatic gain control on the radio that can make the RSSI reading 
non-linear and inconsistent as gain is added to the rx circuit. Use at your 
own discretion.

 

Содержание RBM101H-345

Страница 1: ...Wireless Receiver For 319MHz Sensors RBM101i 319 User Guide VERSION 0 1 APRIL 2017...

Страница 2: ...2 Messages from the Module 6 3 2 1 CMD Command Response 7 3 2 2 ERR Error Message 7 3 2 3 STA Status Message 7 3 2 4 SEN Sensor Message 8 3 3 AT Command Reference 9 3 3 1 AT Commands 9 3 3 1 1 AT Att...

Страница 3: ...USER GUIDE PAGE 2 OF 19 4 3 Error Messages 14 5 CONFIGURATION 16 5 1 Bootloader 16 5 1 1 Using Terminal Emulators 16 6 MECHANICAL DRAWINGS 18 7 TRADEMARKS AND COPYRIGHT 19 8 DISCLAIMERS WARRANTY AND...

Страница 4: ...tallations home automation systems life safety products and more The RBM101i 319 compatibility list includes but is not limited to 319MHz sensors from the following manufacturers UTC Interlogix ITI Qo...

Страница 5: ...ATIONS 2 1 General Specifications The following table provides the general specifications for the RBM101i Table 2 RBM101i General Specifications Specification Value Operating Frequency 319 508MHz Chan...

Страница 6: ...1 Vcc Power supply 2 UART_TX Out UART data out 3 UART_RX In UART data in 4 N C Not connected 5 nReset In Device is reset when held low 6 N C Not connected 7 N C Not connected 8 N C Not connected 9 N C...

Страница 7: ...ed as the ASCII string 12 which allows for convenient control through a terminal emulator Host processors communicating to the module through a UART must convert values to ASCII coded values 3 1 Comma...

Страница 8: ...1 01 the response would be CMD 0101 3 2 2 ERR Error Message This is an error message from the module that sends a 4 digit error code as ASCII coded hex characters For instance error code 0x0000 would...

Страница 9: ...yte 1 byte 1 byte 3 bytes 1 byte Sensor ID This is the unique 24 bit sensor ID that is usually printed on a sticker on the enclosure of the sensor Message Count With every new sensor event this field...

Страница 10: ...ng process where a bootloader delay is used to determine if the device is ready 3 3 1 1 AT Attention This is the basic standalone command to determine if a device is available out of reset boot loadin...

Страница 11: ...eout This command changes the time that the bootloader waits for the DEL character prior to booting the application The parameter is a 4 digit ASCII coded hex value and is in units of milliseconds Def...

Страница 12: ...ble 9 Baud Rate Parameter Baud Rate 0 1 200 1 2 400 2 4 800 3 9 600 4 19 200 5 38 400 6 57 600 7 115 200 8 230 400 If the baud rate setting is successful the module will respond with a CMD OK at the o...

Страница 13: ...er is a 16 bit value in units of 10ms Default 01F5 5 seconds This does not block new events from the same sensor that fall within this window Each new event should contain an updated message count whi...

Страница 14: ...provided here to give the user basic functionality It is highly recommended to test all boundary conditions for each sensor to be used in an end application and verify the tables for that use case In...

Страница 15: ...aracters ERR as defined in the Serial Commands section This error codes are defined in the following table Table 12 Error Messages Code Error Description 0003 Not Ready for new commands The host is at...

Страница 16: ...carrier or test packets failed 001f Write to flash failed An attempted write to flash failed 0020 Radio receive config failed The configuration of the radio receiver failed 0021 Radio transmit data lo...

Страница 17: ...ytime the device is reset which allows the user to program a new image even if the current image has become corrupt When running a terminal program the following is displayed when the bootloader is en...

Страница 18: ...ded by Radio Bridge are signed and encrypted meaning that they cannot be loaded on other hardware and no other firmware images can be loaded on the module through the bootloader Note that the bootload...

Страница 19: ...RADIO BRIDGE RBM101I USER GUIDE COPYRIGHT 2017 RADIO BRIDGE INC RADIO BRIDGE RBM101I USER GUIDE PAGE 18 OF 19 6 MECHANICAL DRAWINGS...

Страница 20: ...warranty of any kind expressed or implied including but not limited to the implied warranties of fitness or merchantability for a particular purpose Radio Bridge may make improvements and or changes...

Отзывы: