Status Messages
This section defines status messages that are sent from the module back to the host over the
serial port.
The status message begins with the ASCII characters “STA “ an as defined in the
Serial
Commands
section. These error codes are defined in the following table.
Table 11 Status Messages
Code
Status
Description
0000
Device reset
Device just came out of reset
4.3.
Error Messages
This section defines the error messages that are sent from the module back to the host over
the serial port. The message begins with the ASCII characters “ERR” as defined in the
Serial
Commands
section. This error codes are defined in the following table:
Table 12 Error Messages
Code
Error
Description
0003
Not Ready for new
commands
The host is attempting to send new commands but the
device is not ready to receive new commands yet.
0004
Incorrect command
format
The format of the serial command sent to the device is
wrong.
0009
Not ASCII coded
hex
The values provided were not ASCII coded hex values.
000a
Command not
recognized
A command was sent to the device that was not
recognized
0012
Invalid parameter
The parameter used in the AT command is invalid
0017
Radio init failed
Initialization of the radio failed
0018
Radio receive
overflow
Radio receiver overflow condition, radio is reset
Note that status messages do not include errors. Error messages are defined
in the section
Error Messages
.