![Radio Bridge RBM101 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/radio-bridge/rbm101/rbm101_user-manual_777783024.webp)
R
ADIO
B
RIDGE
RBM101
U
SER
G
UIDE
C
OPYRIGHT
©
2017,
R
ADIO
B
RIDGE
I
NC
.
R
ADIO
B
RIDGE
RBM101
U
SER
G
UIDE
P
AGE
23
OF
35
000f
Packet already in
queue
Host is attempting to queue a new packet but there is
already a packet in the queue.
0010
Session key not set
An attempt to enable an encryption function failed
because the session key is not yet set
0011
Provisioning key
not set
An attempt to enable an encryption function failed
because the provisioning key is not yet set
0012
Invalid parameter
The parameter used in the AT command is invalid
0013
Endpoint not
registered
The endpoint specified is not registered with the
coordinator
0014
Reported ack
failures increased
The number of ack failures reported by an endpoint
through a supervisory message has increased since the
last supervisory message.
0015
Reported out of
sequence packets
increased
The number of out of sequence packets reported by an
endpoint through a supervisory message has increased
since the last supervisory message.
0016
Unexpected ack
received
Device received an ack but was not waiting for one
0017
Radio init failed
Initialization of the radio failed
0018
Radio receive
overflow
Radio receiver overflow condition, radio is reset
0019
Radio receive start
failed
An attempt to start the radio receiver failed
001a
Radio config failed
Configuration of the radio during initialization failed
001b
Radio receive out
of memory
The radio receive buffer is out of memory, packet receive
failed
001c
Radio transmit
underflow
Radio transmit underflow condition
001d
Radio transmit
channel busy
Radio transmit channel busy condition
001e
Test mode
command failed
An action related to a test mode (test carrier or test
packets) failed.