5.
M
ESSAGES
5.1.
Status Messages
This section defines status messages that are sent from the module back to the host over the
serial port.
The status message begins with the ASCII characters “STA “ and is followed by a Device ID if
relevant as defined in the
Serial Commands
section. These error codes are defined in the
following table.
Table 10 Status Messages
Code
Status
Description
0000
Device reset
Device just came out of reset
0001
Sleepy supervisory
received
A supervisory message from a sleepy endpoint just
arrived. The host has a period of time defined by the
Listen Window to send messages to the endpoint before
it re-enters sleep mode.
0002
Queued message
sent to sleepy
endpoint
The message we queued for the sleepy endpoint has
been sent in the listen window.
0003
Supervisory now
current
Coordinator received a supervisory message from an
endpoint that was not previously reporting
5.2.
Error Messages
This section defines the error messages that are sent from the module back to the host over
the serial port. The message begins with the ASCII characters “ERR” as defined in the
Serial
Commands
section. This error codes are defined in the following table:
Table 11 Error Messages
Code
Error
Description
0000
No ack
No ack has been received after transmitting data after
retries have been exhausted.
Note that status messages do not include errors. Error messages are defined
in the section
Error Messages
.