36000 Kraljevo, Živojina Lazića
- Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: [email protected]
94
Possible cause 4
CAUSE 4
–
Deep area of the combustion space where the pellets are burning is full of
unburnt residues, i.e. of the slag so that there is no contact of pellets and hot air.
The procedure for troubleshooting 4
–
Clean the deep area of the combustion chamber,
first clean the rough particles of slag mechanically and the fine slag can be removed by
means of vacuum cleaner.
Possible cause 5
CAUSE 5
–
Pellets used are of high humidity.
The procedure for troubleshooting 5
–
Try to use pellet that has a higher level of
dryness.
Possible cause 6
CAUSE 6
–
Electric supply voltage onto which the boiler is connected is much lower
than 220-230V so the capacity of the heater is lower.
The procedure for troubleshooting 6
–
Connect the AC Voltage adapter or ignite
manually.
Possible cause 7
CAUSE 7
–
After the manual setting and automatic addition in the ignition area the pellet
level is such that the pellet is not in contact with the heater.
The procedure for troubleshooting 7
–
Re-charge the level of pellets.
Possible cause 8
CAUSE 8
–
The boiler is set from automatic to manual mode of operation. If, along the
whole phase of ignition, the heater lamp is not lighted, then we are sure that the boiler is
in manual mode.
The procedure for troubleshooting 8
–
Switch the boiler into automatic ignition.
Possible cause 9
CAUSE 9
–
Faulty electric heater for ignition.Switch off the boiler from the mains
supply and on the the electrical heater cords measure the resistance.
The procedure for troubleshooting 9
–
Change electric heater.