Radiation Alert Inspector EXP+ Скачать руководство пользователя страница 4

Figure 2 End Panel View

The Display

The LCD (liquid crystal display) shows various indicators according to the mode setting, function being performed, and
battery condition.

Figure 3 

Display Indicators

Indicators:

The 

numeric display (A)

shows the current radiation level in the unit specified by the mode switch setting.

A small 

battery (B)

appears to the left of the numeric display indicating low battery voltage.

A

Radiation Symbol (C)

Appears to the left of the numeric display when the Alert mode is activated.

An 

hourglass (D)

appears to the left of the numeric display while in the Cal mode or during a timed count.

TOTAL (E) 

appears when the Inspector

+

is in Total/Timer mode. 

X1000 (F)

appears when the numeric display is to be multiplied by 1000.

CAL (G) 

is shown while you are calibrating the Inspector

+

.

SET (H)

appears when you are setting the timer (the numeric display shows the timed period instead of the 

current radiation level), in the Cal mode (the numeric display shows the Cal factor instead of the current  radiation 

level), and while adjusting settings in the Utility and Alarm Menus.

The current 

unit of measurement (I)—CPM, CPS, mR/hr or 

µµ

Sv/hr—

is displayed to the right of the numeric 

display. 

The Switches

The Inspector

+

has two switches on the front, and one switch and three buttons on the end panel.  Each switch has three

settings which are described below.

Mode Switch (Figure 1(2))

mR/hr  

µµ

Sv/hr

.  The numeric display shows the current radiation level in milliroentgens per hour or, when SI units are

used, in microsieverts per hour.
In mR/hr mode, the Inspector

+

displays the radiation level from .001 to 100.

In 

µ

Sv/hr mode, the Inspector

+

displays the radiation level from .01 to 1000.  See “Utility Menu” in Chapter 3 for

details on how to activate this mode.

CPM  CPS

.  In CPM, the display shows the current radiation level in counts per minute from 0 to 350,000.  When

X1000

is shown on the display, multiply the numeric reading by 1000 to get the complete radiation level.  When using

SI units, the display shows the radiation level in counts per second from 0 to 5000.

Total/Timer. 

The display shows the accumulated total of counts from 1 to 9,999,000.  When 

X1000

is shown on the

display, multiply the numeric reading by 1000 to get the complete radiation level.  Totaling starts when the switch is

moved to this position.  For details, see “Taking a Timed or Total Count” in Chapter 3.

Off/On/Audio Switch (Figure 1 (3))

Audio.

The Inspector

+

is on and makes a clicking sound for each radiation event detected.

On.

The Inspector

+

is operating, but audio is off.

Off.

The Inspector

+

is not operating.

4

(4) Timer Switch

(6) Plus & Minus Buttons

(5) Set Button

GM Center Indicator

(A) Numeric Display

(B) Low Battery

(C) Alert

(D) Timer

(E) Total

Mode

(I) Units of

Measurments

(H) Utility Menu, Timer,

Calibation, Alarm 

Set Mode

(G) CAL

Mode

(F) X1000

Mode

Содержание Inspector EXP+

Страница 1: ...User Manual...

Страница 2: ...lity Menu 7 Options 8 4 Common Procedures 8 Establishing the Background Count 8 Environmental Area Monitoring 8 Checking for Surface Contamination 8 5 Maintenance 9 Calibration 9 Calibrating Using a S...

Страница 3: ...spector in temperatures over 100 F 38 C or in direct sunlight for extended periods of time Do not get the Inspector wet Water can damage the circuitry and the mica surface of the Geiger tube Do not pu...

Страница 4: ...nel Each switch has three settings which are described below Mode Switch Figure 1 2 mR hr Sv hr The numeric display shows the current radiation level in milliroentgens per hour or when SI units are us...

Страница 5: ...et through the plastic case to penetrate the mica surface of the tube The small radiation symbol Figure 1 7 on the front label indicates the center of the Geiger tube External For Inspector EXP only T...

Страница 6: ...ility Menu detailed in Chapter 3 Refer to the following table After 30 second start up the reading will be based if instrument is detecting on an average of the previous 100 CPS 30 seconds 6000 CPM or...

Страница 7: ...e Using Dose Rate Modes While Timer is On Dose rate modes can be used while the timer is on In any dose rate mode the hour glass indicator will continue to flash during a timed period At the end of th...

Страница 8: ...e information on using the timer see Taking a Timed Count in Chapter 3 A ten minute average is moderately accurate You can repeat it several times and see how close the averages are To establish a mor...

Страница 9: ...nt down timer sound 11 Turn off the Inspector Hold down the button on the end panel and turn on the Inspector The display shows CAL and the Inspector counts down for 15 seconds chirping each second Th...

Страница 10: ...L and the hourglass icon flashing At the end of the 30 seconds it beeps The display shows CAL and SET is flashing 7 Press the and buttons to adjust the reading to what it should be When the reading is...

Страница 11: ...ta radiation A beta particle consists of an electron emitted from an atom It has more mass and less energy than a gamma ray so it doesn t penetrate matter as deeply as gamma and X rays Alpha radiation...

Страница 12: ...r 3 Operation Autoranging Display update CAL Factor Range 001 to 199 Timer Can set 1 10 minute sampling periods in one minute increments 10 50 minute sampling periods in 10 minute increments and 1 24...

Страница 13: ...or carrying the instrument Appendix C Inspector EXP Carrying Case The reinforced protective probe cover prevents damage to the fragile window of the detector The front flap lifts out of the way to gai...

Страница 14: ...m Observer Software The Observer software runs on a Windows platform and can be used with the Inspector Digilert 50 and Geiger Radiation Monitors As an option any of our Radiation Alert instruments ca...

Страница 15: ...onform to the warranty at any time while this warranty is effective the Warrantor will repair the defect and return the instrument to you prepaid without charge for parts or labor NOTE While the produ...

Страница 16: ...e company serial no Inside battery compartment or rear label address City state zip code 4 calibrations per year circle 1 2 3 4 phone number date placed in service Mail to Attn Robert Russell S E Inte...

Отзывы: