Installation Manual 

COMBI - TA05A005.C0604

 

6

 

GENERAL INSTALLATION REQUIREMENTS 

 

GAS SAFETY 

 
It is the law that all gas appliances are installed by a CORGI registered installer (you can check this by contacting corgi on 
01256.372200) in accordance with the regulations listed below.  Failure to install appliances correctly could lead to prosecution.  It is in 
your own interest and that of safety to ensure that the law is complied with.  Failure to have your appliance installed to comply with the 
installation instructions and the requirements listed below could invalidate your guarantee. 
 

RELATED DOCUMENTS 

The installation of the boiler must be in accordance with the relevant requirements of the Gas Safety regulations, Building regulations, 
I.E.E. regulations and the bylaws of the local water authority. 
It should be in accordance also with any relevant requirements of the local authority and the relevant recommendations of the following 
British Standard Codes of Practice: 
 
 

B.S 6400: 

1985  & B.S. 6891 : 1988. 

 

BS 5376: 

Selection and Installation of Gas Space Heating ( 1 and 2 family gases) 

 

 

Part 2: Boilers of rated input not exceeding 60 Kw 

 

BS 5449: 

Central Heating for domestic premises 

 

 

Part 1: Forced circulation Hot Water System 

 

CP 342: 

Centralised Hot Water Supply BS 6700 : 

1987 

 

 

Part 2: Buildings other than individual 

 

BS 5440: 

Flues and air supply for Gas Appliances of rated input not exceeding 

 

 

60 Kw (1 and 2 family gases) 

  

Part 

1: 

Flues 

 

 

Part 2: Air Supply 

 

BS 5446: 

1990:  Installation of Gas Hot Water supplies for domestic purposes 

 

GAS SUPPLY 

Service Pipes:  The local gas region should be consulted at the installation planning stage in order to establish the availability of supply 
of gas.  An existing service pipe must not be used without prior consultation with the local gas region. 
Meters:  A gas meter is connected to the service pipe by the local gas region or local gas region contractor. An existing meter should be 
checked to ensure that it is capable of passing an additional 3.4 m3/hr (125 ft/hr)  before the appliance is installed.  The meter outlet 
governor should ensure a nominal dynamic pressure of 20m Bar, (8 in wg) at the boiler.  Installation pipes should be fitted in 
accordance with BS6891.1988.  

Pipework that supplies the boiler must be a 22 mm. ininterrupted supply from meter to the 

isolation cock of the boiler.

 The complete installation must be tested for soundness as described in the above code, BS 6400: 1985 & 

BS6891. 
 
IMPORTANT:  BOTH THE USER AND THE MANUFACTURER RELY UPON THE INSTALLER, WHOSE JOB IS TO INSTALL THE 
BOILER AND CONNECT IT TO A CORRECTLY DESIGNED HEATING SYSTEM.  THE INSTALLER SHOULD ACQUAINT HIMSELF 
WITH THE CONTENTS OF THIS PUBLICATION AND THE RELEVANT BRITISH STANDARDS CONCERNING INSTALLATION 
REQUIREMENTS. 
 

LOCATION OF BOILER 

In siting the combination boiler, the following limitations MUST be observed: 
The position selected for installation should be within the building, and MUST allow  
adequate space for installation, servicing and operation of the combination boiler, and for air circulation around it. The boiler is not 
suitable for external installation. 
This position MUST also allow for a suitable flue termination to be made.  The boiler must be installed on a flat vertical wall which is 
capable of supporting the weight of the combination boiler, and any ancillary equipment. 
If  the boiler is to be fitted in a timber framed building it should be fitted in accordance with the British Gas publication "Guide for Gas 
Installations in Timber Frame Housing, Reference IGE/UP/6. If in doubt, advice must be sought from the local  region of British Gas. 
The boiler may be installed in any room or internal space, although particular attention is drawn to the requirements of the current I.E.E. 
Wiring Regulations, and in Scotland the electrical provisions of the Building Regulations applicable in Scotland, with respect to the 
installation of the boiler in a room or internal space containing a bath or shower. 
Where a room-sealed appliance is installed in a room containing a bath or shower, any electrical switch or appliance control utilising 
mains electricity must be so situated that it cannot be touched by a person using the bath or shower. 
A compartment used to enclose the combination boiler MUST be designed and constructed specifically for this purpose.  An existing 
cupboard, or compartment, may be used provided it is modified accordingly. 

Содержание RBS 20 E

Страница 1: ...A05A005 C0604 Technical Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED WALL HUNG BOILERS Model RBS 20 E TYPE C ROOM SEALED SEDBU...

Страница 2: ......

Страница 3: ...MENTS page 6 BOILER INSTALLATION page 8 ELECTRICAL CONNECTIONS page 10 BOILER CONTROL PANEL page 11 STARTING UP THE BOILER FOR THE FIRST TIME page 11 REGULATING THE GAS PRESSURE page 13 GAS TYPE CONVE...

Страница 4: ...VE 73 23 EEC Low voltage GAS DIRECTIVE 89 336 EEC Electromagnetic compatibility GAS DIRECTIVE 92 42 ECC requirements for new hot water boilers fired with liquid or gaseous fuels All RADIANT boilers ar...

Страница 5: ...fessionally qualified personnel according to the constructor s instructions Whenever the device is to be put out of service secure all potentially hazardous parts to prevent accidents or damage If the...

Страница 6: ...esidues that might negative effect the operation of the boiler 3 GENERAL WARNINGS BASED ON TYPE OF POWER SUPPLY POWER SUPPLY Electrical safety is achieved only when the device is correctly and efficie...

Страница 7: ...ciency 92 80 30 output efficiency 89 30 GAS DIRECTIVE 92 42 ECC stars 2 NOx class European Standard UNI EN 297 pr A5 class 2 Max heating temperature C 35 80 Max working pressure heating bar 3 Min work...

Страница 8: ...flue duct and the air intake directly from an external wall N B To insert a bend in the flue reduce total flue length by 1 5 m R RETURN C HOT WATER 1 2 G GAS 1 2 F COLD WATER 1 2 A HEATING FLOW NOTE...

Страница 9: ...c pressure of 20m Bar 8 in wg at the boiler Installation pipes should be fitted in accordance with BS6891 1988 Pipework that supplies the boiler must be a 22 mm ininterrupted supply from meter to the...

Страница 10: ...g systems If this should occur the appliance MUST BE TURNED OFF IMMEDIATELY and the local gas region consulted Where the lowest part of the terminal is fitted less than 2m 6 6ft above a balcony above...

Страница 11: ...e boiler on the wall using the fixing screws or brackets and make all necessary pipe connections WATER CONNECTIONS To facilitate installation the boiler is equipped with a fittings kit fig 3 IMPORTANT...

Страница 12: ...ust be carried out by a qualified corgi registered fitter ANTI FREEZE SYSTEM The boiler is equipped with an anti freeze system which comes into operation when the temperature falls to 5 C heating sens...

Страница 13: ...r screws on the housing and open the electrical control box by lifting the cover as shown in fig 1 E With the electrical control box now open make the following connections Connect the yellow green wi...

Страница 14: ...carried out with the boiler working make sure the electrical mains switch is OFF remove the front cover by pulling it forwards undo the side screws and rotate the panel downwards FILLING THE SYSTEM F...

Страница 15: ...t the front casing back REGULATING THE HEATING TEMPERATURE The heating temperature is regulated by turning knob 2 fig 1 pag 11 to the temperature required chosen from the different values printed arou...

Страница 16: ...d with the selector set to 7 winter set the P1 MAX HEAT trimmer to the minimum heat by turning it counter clockwise regulate the minimum pressure by turning the P2 MIN GAS trimmer see the table below...

Страница 17: ...thod to check for gas leaks each time gas connections are dismantled and reassembled d replace the gas setting plate that indicates the type of gas and nominal pressure for the boiler When converting...

Страница 18: ...g an electromagnetic principle with electrical switching by means of a relay The device is made of non toxic corrosion proof ZYTEL 101 L plastic material which has type approval with non toxic charact...

Страница 19: ...tion Manual COMBI TA05A005 C0604 16 ELECTRICAL CONNECTION RBS 20 E IMPORTANT RESPECT LIVE NEUTRAL POLARITY POWER SUPPLY TERMINAL BLOCK M2 M4 M6 TA OR M3 M4 PA M6 M3 M1 M5 M7 M2 M7 M5 S4565QM 1012 CIRU...

Страница 20: ...Installation Manual COMBI TA05A005 C0604 17 RBS 20 E WIRING DIAGRAM...

Страница 21: ...boiler When dismantling the boilers casing be careful when removing the side panels after having removed the front panel the side panels are removed by undoing the lower and front fixing screws and th...

Страница 22: ...minimum power d ignition board wires reserved colour grey brown d connect properly 5 the pump circulates and the fan runs the flame ignites but after 10 seconds stops and locks out e live neutral wir...

Страница 23: ...5 5 3 9 36066LA ELECTRONIC GAS VALVE VK4105 G1112 9 37012LA EXHAUST FAN 9 47021LA 3 POSITION COMMUTATOR SWITCH R11C2X401 9 58008LA MAIN HEAT EXCHANGER 9 59001LA AIR PRESSURE SWITCH C6065AH1095 9 59015...

Страница 24: ...LET HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET E OE ALL RIGHTS...

Отзывы: