R1K 34 /B - RAD - ING - Manuale - 1512.2_CSA_TTS
3. USE
USER
3.1.9. FAULT SIGNALLING CODES
The boiler might signal some faults by displaying a code. Below you have a list of the codes and of the
operations to be performed in order to unlock the boiler.
CODE
ICON
FAULT
INTERVENTION
E01
FLAME FAILURE
MAKE SURE THAT THE BOILER AND SUPPLY GAS VALVES ARE
OPEN.
PRESS THE RESET ‘
’ BUTTON ON THE CONTROL PANEL TO
RESET THE FAULT, AS SOON AS THE ERROR CODE DISAPPEARS
FROM THE DISPLAY, THE BOILER WILL START AUTOMATICALLY.
IF THE ERROR PERSISTS CONTACT A QUALIFIED SERVICE
TECHNICIAN.
E02
WATE TEMP. HIGH LIMIT SWITCH (95 °C)
PRESS THE RESET ‘
’ BUTTON ON THE CONTROL PANEL TO
RESET THE FAULT, AS SOON AS THE ERROR CODE DISAPPEARS
FROM THE DISPLAY, THE BOILER WILL START AUTOMATICALLY.
IF THE ERROR PERSISTS CONTACT A QUALIFIED SERVICE
TECHNICIAN.
E03
EXHAUST SAFETY HIGH LIMIT SWITCH
(102 °C)
CONTACT A QUALIFIED SERVICE TECHNICIAN.
E04
WATER MISSING IN THE SYSTEM
IF THE SYSTEM PRESSURE IS BELOW 1.2 BAR, FILL THE SYSTEM
AS DESCRIBED IN “SYSTEM FILLING”.
IF THE ERROR PERSISTS CONTACT A QUALIFIED SERVICE
TECHNICIAN.
E05
HEATING PROBE
CONTACT A QUALIFIED SERVICE TECHNICIAN.
E06
DOMESTIC INLET TEMP. PROBE
CONTACT A QUALIFIED SERVICE TECHNICIAN.
E15
RETURN PROBE
CONTACT A QUALIFIED SERVICE TECHNICIAN.
E16
COMBUSTION BLOWER
CONTACT A QUALIFIED SERVICE TECHNICIAN.
E18
INSUFFICIENT CIRCULATION
CONTACT A QUALIFIED SERVICE TECHNICIAN.
USE
Содержание R1K 34
Страница 6: ......
Страница 62: ......
Страница 65: ...65 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Страница 66: ...66 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Страница 67: ...67 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Страница 68: ...68 R1K 34 B RAD ING Manuale 1512 2_CSA_TTS 3 USE USER...
Страница 79: ......